background image

© Panasonic Corporation 2016.

 

 

 

Air-to-Water Hydro Tank 

 

 

Indoor Unit

Outdoor Unit

WH-ADC0309H3E5

WH-UD03HE5-1
WH-UD05HE5-1
WH-UD07HE5-1
WH-UD09HE5-1

Destination

Europe

Turkey

 

 

 

 

 

 

IMPORTANT SAFETY NOTICE

There are special components used in this equipment which are important for safety. These parts are marked by

in the Schematic

Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced
with manufacturer’s specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of
manufacturer.

!

 

WARNING 

This service information is designed for experienced repair technicians only and is not designed for use by the general public. 

It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. 

Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to 

service or repair the products dealt with in this service information by anyone else could result in serious injury or death. 

 

PRECAUTION OF LOW TEMPERATURE 

In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.

 

Summary of Contents for WH-ADC0309H3E5

Page 1: ...o not modify the original design without permission of manufacturer WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public It does not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired o...

Page 2: ...ill onto the Tank Unit 9 Do not use joint cable for Tank Unit Outdoor Unit connection cable Use specified Tank Unit Outdoor Unit connection cable refer to instruction CONNECT THE CABLE TO THE TANK UNIT and connect tightly for Tank Unit Outdoor Unit connection Clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire...

Page 3: ...over that secured by screws must be carried out under the supervision of authorized dealer licensed installation contractor skilled person and instructed person 34 This unit must be properly earthed The electrical earth must not be connected to a gas pipe water pipe the earth of lightning rod or a telephone Otherwise there is a danger of electrical shock in the event of an insulation breakdown or ...

Page 4: ...xpansion Valve Refrigeration Oil cm 3 FV50S 450 Refrigerant R410A kg oz 1 20 42 4 Dimension Height mm inch 622 24 1 2 Width mm inch 824 32 15 32 Depth mm inch 298 11 24 32 Net Weight kg lbs 39 86 Pipe Diameter Liquid mm inch 6 35 1 4 Gas mm inch 12 70 1 2 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 15 49 2 I D O D Height Difference m ft 5 16 4 Additional Gas Amount g m oz ft 20 0 2 Re...

Page 5: ...r Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 20 55 Internal Pressure Differential kPa Cooling 5 0 Heating 5 0 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 28 Heating 28 Power Level dB Cooling 41 Heating 41 Dimension Height mm inch 717 28 7 32 Width mm inch 598 23 17 32 Depth mm inch 1800 70 27 32 Net Weigh...

Page 6: ...erial EN 1 4521 Volume L 185 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heating capacities are based on outdoor air temperature of 7 C D...

Page 7: ... Valve Refrigeration Oil cm 3 FV50S 450 Refrigerant R410A kg oz 1 20 42 4 Dimension Height mm inch 622 24 1 2 Width mm inch 824 32 15 32 Depth mm inch 298 11 24 32 Net Weight kg lbs 39 86 Pipe Diameter Liquid mm inch 6 35 1 4 Gas mm inch 12 70 1 2 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 15 49 2 I D O D Height Difference m ft 5 16 4 Additional Gas Amount g m oz ft 20 0 2 Refrigerat...

Page 8: ...st Condition EN 14511 Operation Range Outdoor Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 20 55 Internal Pressure Differential kPa Cooling 10 0 Heating 12 0 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 28 Heating 28 Power Level dB Cooling 41 Heating 41 Dimension Height mm inch 717 28 7 32 Width mm inch 598 ...

Page 9: ... Bar 3 5 Pressure Vessel Material En 1 4521 Volume L 185 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heating capacities are based on outd...

Page 10: ...alve Refrigeration Oil cm 3 FV50S 900 Refrigerant R410A kg oz 1 45 51 2 Dimension Height mm inch 795 31 5 16 Width mm inch 900 35 7 16 Depth mm inch 320 12 19 32 Net Weight kg lbs 66 146 Pipe Diameter Liquid mm inch 6 35 1 4 Gas mm inch 15 88 5 8 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 30 98 4 I D O D Height Difference m ft 20 65 6 Additional Gas Amount g m oz ft 30 0 3 Refrigerat...

Page 11: ...N 14511 Operation Range Outdoor Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 20 55 Internal Pressure Differential kPa Cooling 16 0 Heating 21 0 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 28 Cooling 28 Power Level dB Cooling 41 Cooling 41 Dimension Height mm inch 717 28 7 32 Width mm inch 598 23 17 32 Depth...

Page 12: ... Bar 3 5 Pressure Vessel Material En 1 4521 Volume L 185 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heating capacities are based on outd...

Page 13: ...alve Refrigeration Oil cm 3 FV50S 900 Refrigerant R410A kg oz 1 45 51 2 Dimension Height mm inch 795 31 5 16 Width mm inch 900 35 7 16 Depth mm inch 320 12 19 32 Net Weight kg lbs 66 146 Pipe Diameter Liquid mm inch 6 35 1 4 Gas mm inch 15 88 5 8 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 30 98 4 I D O D Height Difference m ft 20 65 6 Additional Gas Amount g m oz ft 30 0 3 Refrigerat...

Page 14: ...EN 14511 Operation Range Outdoor Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 20 55 Internal Pressure Differential kPa Cooling 21 0 Heating 33 0 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 28 Cooling 28 Power Level dB Cooling 41 Cooling 41 Dimension Height mm inch 717 28 7 32 Width mm inch 598 23 17 32 Dept...

Page 15: ... Bar 3 5 Pressure Vessel Material En 1 4521 Volume L 185 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heating capacities are based on outd...

Page 16: ...nction o Weekly timer setting A class energy efficiency pump o Water pump speed can be set by selection at control panel Improved deice cycle Protection Feature o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compressor Serviceability Feature o Breakdown Self Diagnosis function o System ...

Page 17: ...or d Water Pressure Gauge e Front Plate f h g Top Plate Right Plate Left Plate i Rear Plate j Tank Sensor Not Visible k Safety Relief Valve Connector name Water Inlet From Space Heating Cooling a Water Outlet To Space Heating Cooling b Cold Water Inlet Domestic Hot Water Tank c Hot Water Outlet Domestic Hot Water Tank d Refrigerant Gas e Refrigerant Liquid f Domestic Hot Water Tank Discharge Drain...

Page 18: ...Outdoor Unit UD03_05HE5 1 UD07_09HE5 1 Air inlet rear Air inlet side Air outlet Air inlet rear Air inlet side Air outlet ...

Page 19: ...Dimensions Indoor Unit Top View Bottom View Front View Side View Unit mm 70 1080 612 60 478 60 36 598 717 ...

Page 20: ...UD03HE5 1 WH UD05HE5 1 Top View Space necessary for installation Anchor Bolt Pitch 355 x 260 100 cm 10 cm Front View Side View Unit mm Side View 823 4 68 5 37 622 23 69 61 298 540 124 21 9 160 53 4 32 97 167 330 10 cm ...

Page 21: ...WH UD07HE5 1 WH UD09HE5 1 Unit mm Top View Front View Back View Side View Side View 391 900 253 110 320 218 318 5 355 181 795 410 0 2 6 0 4 1 175 140 300 260 176 24 10 30 DD 30 10 320 20 15 40 400 ...

Page 22: ...ER OUTLET TEMP SENSOR WATER TANK TEMP SENSOR WATER INLET TEMP SENSOR WATER OUTLET TEMP SENSOR 3 WAY VALVE AIR TEMP SENSOR HEAT EXCHANGER HEAT EXCHANGER WATER TANK WATER DISCHARGE VALVE FLOOR HEATING WATER OUTLET FLOOR HEATING WATER INLET SANITARY HOT WATER OUTLET SANITARY COLD WATER INLET STRAINER CU UD07 09HE5 1 MUFFLER CU UD03 05HE5 1 STRAINER COMPRESSOR 4 WAY VALVE TANK TEMP SENSOR DISCHARGE TE...

Page 23: ...IT WATER PIPING CONNECTING BAR G WATER PIPING CONNECTING BAR G 1 BL 2 W 3 R AC1 L3 BLK AC1 N WHT G RED WHITE W W W W DATA RED G02 GRN CN PUMP1 WHT 1 4 5 6 7 HT1 L3 RED AC2 L3 BLK AC2 N2 WHT RY HT L3 SW1 SW2 OUTDOOR AIR SENSOR EXTERNAL CONTROL 1 BOILER CONTACT EXTRA PUMP RY CONTACT1 TANK SENSOR t t t 80 3 C TERMINAL BOARD GROUNDING GROUNDING TO OUTDOOR UNIT BACKUP HEATER 3kW OLP BOOSTER HEATER ROOM...

Page 24: ...IT COMMUNICATION CIRCUIT OUTDOORAIRTEMP SENSOR THERMISTOR YELLOW YLW BLUE BLU RED RED TRADEMARK COMPRESSOR TERMINAL THE PARENTHESIZED LETTERSARE INDICATED ON TERMINALCOVER PIPING TEMP SENSOR THERMISTOR CN TH1 WHT CN TANK WHT CN DIS WHT CN HOT WHT CN STM WHT CN HPS RED U RED V BLU W YLW RED RED WHT BLK BLU YLW HIGH PRESSURE SENSOR M COMPRESSORTEMP SENSOR THERMISTOR DISCHARGE TEMP SENSOR THERMISTOR ...

Page 25: ...FG1 GREEN BLACK CAPACITOR ELECTRONIC CONTROLLER 3 W V U YELLOW BLUE RED W V U N P FAN MOTOR M 7 4 RED G CN DIS BL T3 15A L250V FUSE1 CN FM1 BL 1 BLACK DCN BLUE AC C RED DCP 1 2 CIRCUIT RECTIFICATION W UNIT GRAY 2 1 AC L WHITE CN RY1 WHITE CN WHT BLACK 4 1 3 AC BLK01 CIRCUIT PFC NOISE FILTER CIRCUIT RY HOT CN HPS WHITE CN HT1 BLUE RY HT1 3 1 RY HT2 CN HOT HEATER 3 M R INDOOR CN WHT WHITE RED COM3 S...

Page 26: ... SFA21 1 VVI46 2 PAW A2W RT PAW A2W RTW 167032 Yonos 25 PAW A2W T PAW A2W T PAW A2W T PAW A2W T PAW A2W T y accessorie m od e g l not as ot ked ion S 18 5 TWIRED WIRELESS 2 5 6 TSBU TSOD TSHC TSRT TSSO es listed in ab 11 1 1 2 Be care not dam Only re reached It may n installat cause in The Tan or horiz o If it of p mus o If it on s loca Fix the on an u 11 1 2 T In 1 Mak 2 Inse 3 Fix 4 Cut from Whe...

Page 27: ...an Outd in co ope gua case T ADC Re 1 3 3 s Tank Unit is nasonic Air to door Unit fro ombination w ration and re ranteed Thu e 1 Connect Outdoor Reducin UD03HE piping c Model Tank Unit Ou C0309H3E5 UD U UD U Do not overtigh 2 Please m located the copp 3 Do not u piping F leakage 4 Connect o Alig tigh o Fur wre the efrigerant s designed fo o Water Hea m other man with Panason eliability of th us wa...

Page 28: ...ion ons etail 0 5 mm opper pe Do not ov Make s prevent After ins conditio Failure cause t Protecti If the Ta power s drain th system could d supply i Assemb Corrosi Duplex resistan mainten resistan not gua It is rec collect w occur A Space H Connec connect Connec connect Failure cause t Refer b particul Tank Unit ADC0309H3E B Domest It s stro vessel Tank ci section o Rec exp 3 5 In high 500kPa Val...

Page 29: ...ose or monia gas ten the hose om leaking strated at e Drain ork ncorporated charge t age outlet ontinuously ger than must not zing to ng must not ed 5 n e E 11 Befo refri test verif insta Step 1 2 3 4 The end of t so that the o damage Ke It is recomm pipework Tu positioned a electrical co Drain Elbow Fix the Drain Drain Water Use inner di market This hose m downward d environmen water leakag Guide...

Page 30: ... air conditioning system to test for leaks and mark for repair 2 Any leak detected at this level shall be repaired and retested starting from Step 1 Pressure test NOTE Always recover the refrigerant and Nitrogen gas into recovery cylinder after completion of a test You must use the detection equipment with Detectable Leak Rate of 10 6 Pa m3 s or better Do not use refrigerant as test medium for sys...

Page 31: ...sh loroprene sh heavier cord ng means S Power Sup Cord nit 1 1 1 2 1 1 1 2 damaged by Control Board torque cN cm k 7 196 16 20 6 245 20 25 n other cable L1 N1 L1 N1 y 1 Power Suppl 6 WARNING behind the Con ervice person nd Conne door Unit sha er cord See b oor Unit UD05HE5 1 UD09HE5 1 t and the ter wires as show er Clamper power supply hould have m heathed pow d to the termi See below ta pply Cabl...

Page 32: ...inal board N E P O ge Drain Tap g ing Requir th IEC EN 61 th IEC EN 61 th IEC EN 61 th IEC EN 61 ble system i hat the Powe th IEC61000 face point be uipment to en onnected onl th IEC EN 61 00A per phas ent for the in th IEC EN 61 th IEC EN 61 ble system i hat the Powe erly rge ter m ocal the g rement 1000 3 2 1000 3 3 and 1000 3 2 1000 3 11 a mpedance Z er Supply 2 is 0 3 12 provid etween the u ns...

Page 33: ... Ens che Turn This sup Be bu el 11 11 Ex 1 6 3 Ch Space Heat Expansion V pressure of Total amoun 200 L Inne 5 L If total amou another exp Please keep system wate Ch 1 6 4 sure the RCC ck RCCB EL n on the pow s testing cou plied to the T e careful not to utton when the ectrical shock m Push the T lever would functions no Contact auth malfunction Turn off the If RCCB ELC ON again a 1 7 Insta Room Re...

Page 34: ...n of the Avo bein Mount the Align the c caseandthe of the bottom Cl Conne contro Mountin Controll d type n Make 2 ho ded type n Make 2 ho Cut here with a nipper and remove the burr with a file top case claws of the top enaligntheclaws m case Scre fiel Bottom case Back side T B Claw 2 places ect the remote co g nge the wires along the e case id the wire ng caught top case laws of the top enalignthe...

Page 35: ...n In order to e of the Tank Tank Unit fu wiring and p intervals Th by authorize scheduled in Ma 1 9 1 Se Turn OFF po Set the two CLOSE Take off the Beware of s Clean the m stain Use s Reinstall the back the clip Set the two OPEN Turn ON pow operation W uld be in bet essary adjus ordingly to o erating range not solve the ized dealer n please cle after finish cle heck Wate ircuit ximum water ss than...

Page 36: ... a 5 E 3 0 event direct s ambient tem from wall ce y cause a sho on with high c where it will such as ding the e there is no ct with an n prevention or UD07 E5 l refrigerant s Rate id m 1 4 m 1 4 tional refrige ockage direct ialist oses only art Qty and y 3 and y 2 e Wide t Outdoor unit g cable 4 CORE mm2 gnation 60245 IEC vier cable 1 4 rigerant piping 1 2 erant piping 5 E 66 Opt sunlight or ra m...

Page 37: ...eratur ubber cap fo g ping to Ou using pipe cu are after onto the cop and then tigh rque as state Torque Liquid ø6 35mm 1 4 18 N m ø6 35mm 1 4 18 N m heat insulato wn in right fig ntering ring the P nd then remo amer If burr avoid the met ing the flare D Anchor pitch 05 E5 Drain el are ed arrow mark ndle Core Yoke Ba on according ly and horizo trong wind an ain Water o follow below h is taller tha...

Page 38: ...2 way valve and the 3 way valve o Be sure to check for gas leakage CAUTION If gauge needle does not move from 0 cmHg 0 MPa to 76 cmHg 0 1 MPa in step 3 above take the following measure 1 If the leak stops when the piping connections are tightened further continue working from step 3 2 If the leak does not stop when the connections are retightened repair location of leak 3 Do not release refrigeran...

Page 39: ...ulated piping ping is in the ckness 6 mm m or more etween wires tdoor g terminal e bushing provide the cable and co g strap 3 amp rd cting cable elow m for its ing Requir ction portion a g end to prev room where m or above ed in accessories ord together with rement as mentioned vent water fro e dew may fo AC Conducto inse s to protect cable h the binding stra App DETAIL d in Indoor O om going ins ...

Page 40: ...f minimum e 2 cable sha Bind op cables w these ba Bind op cables these b wer supply cord 7 vice optio al wiring stan rer recomme onic type refe designation 6 ing complian 8VA min 0 5 mm2 m2 of type d mm2 of type ole switch w sheathed or nce compone be less than min 0 3 mm2 0 3 mm2 do perature con nd zone 2 to ed independ 2 x min 1 5 m m2 of type d m2 of type de e shall be 4 all be 3 x min all be 2...

Page 41: ...al device tat ol nsor sor sor ch ressor switch Bind optional cables with these bands Optional PCB pply cord m2 double in ouble insulati m2 double x min 0 3 mm kgf cm nal devices Maxim sulation laye on layer of P insulation lay m2 double in the length of mum cables len 50 50 50 50 50 50 50 50 50 30 30 30 30 30 30 50 50 50 50 Optional cables External contro Outdoor air sen Remote control Room sensor...

Page 42: ... Open Close n Tank Unit pum setup necessar It does no tal cable length ional PCB C 2 Optional Thermostat 2 Zon roo sen Zone 2 room sensor L N Cool He B stat heat Cool te he Optional PCB ort operate by external switc e for relocation a direction For c Prevent water mp capacity is in ry ot work when us shall be 30m o B CZ NS4P H C C O N C O N Opt The 3 way valve 2 way valve Optional Thermostat 1 Zo ...

Page 43: ...HC SSO ed Extern n ut the externa by Panasonic correct exter AW A2W TS of the buffer the sensor p ank surface AW A2W TS er temperatu piping by usi strap and con black ions mm ostat heat open short the 2 contacts Cool necessary ary controller mixture al Device al devices c Please rnal device BU r tank ocket and SHC re of the ng the ntact paste 40 Ø6 93 70 3 Outdoor If the ins exposed tempera the ac...

Page 44: ...NT cable n Optiona or to uit he ctor For opti Power s Recomm For opti Power s close Operati Recomm This section system insta screws mus contractor i al Insert a the top Connec connec ional pump supply AC23 mended part ional mixing supply AC23 ng time 30s mended part n is for authorize aller only Work st only be carried nstallation engi With O a flat head s of the adap ct the other ctor to the c Sl...

Page 45: ...e attach the front cover to the back cover Use the included cord clamp to fix the CN CNT cable to the wall Pull the cable around as shown in the diagram so that external forces cannot act on the connector in the adaptor Furthermore on the Tank Unit end use the included cable tie to fix the cables together Screws CN CNT cable Take care not to pinch the cable Cord clamp Cable tie ...

Page 46: ...te o circulate zo o circulate zo ect as Zone 2 s the pool w pump start c N N only zone pump stop c FF ndition N AND ed 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0 5 Pressure P kpa P Q WH ol culate the wa ne water pum ed through O one 1 water c one 2 water c 2 circuit P2 ater through condition 1 pump will condition 5 10 15 Wa Min Du H ADC0309H ater inside ea mp control W Optional PCB cir...

Page 47: ...or air temperature 7 C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Outdoor Temperature C Input Power kW Outdoor Temperature C Capacity kW 0 400 0 600 0 800 1 000 1 200 1 400 15 11 7 3 1 5 9 13 17 21 25 2 000 2 600 3 200 3 800 4 400 5 000 15 11 7 3 1 5 9 13 17 21 25 ...

Page 48: ...DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 400 0 560 0 720 0 880 1 040 1 200 18 21 24 27 30 33 36 39 42 45 2 400 2 600 2 800 3 000 3 200 3 400 18 21 24 27 30 33 36 39 42 45 ...

Page 49: ...DBT C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 4 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 600 0 720 0 840 0 960 1 080 1 200 18 21 24 27 30 33 36 39 42 45 3 400 3 600 3 800 4 000 4 200 4 400 18 21 24 27 30 33 36 39 42 45 ...

Page 50: ...BT C WBT Indoor water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 400 0 520 0 640 0 760 0 880 1 000 18 21 24 27 30 33 36 39 42 45 3 000 3 160 3 320 3 480 3 640 3 800 18 21 24 27 30 33 36 39 42 45 ...

Page 51: ... Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Piping Length m Input Power kW Piping Length m Capacity kW 0 600 0 620 0 640 0 660 0 680 0 700 3 4 5 6 7 8 9 10 11 12 13 14 15 3 000 3 060 3 120 3 180 3 240 3 300 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 52: ...BT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 0 900 0 940 0 980 1 020 1 060 1 100 3 4 5 6 7 8 9 10 11 12 13 14 15 2 800 2 920 3 040 3 160 3 280 3 400 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 53: ... C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Outdoor Temperature C Input Power kW Outdoor Temperature C Capacity kW 0 800 1 030 1 260 1 490 1 720 1 950 15 11 7 3 1 5 9 13 17 21 25 4 100 4 300 4 500 4 700 4 900 5 100 15 11 7 3 1 5 9 13 17 21 25 ...

Page 54: ...DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 800 1 000 1 200 1 400 1 600 1 800 18 21 24 27 30 33 36 39 42 45 3 200 3 600 4 000 4 400 4 800 5 200 18 21 24 27 30 33 36 39 42 45 ...

Page 55: ...BT C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 14 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 900 1 060 1 220 1 380 1 540 1 700 18 21 24 27 30 33 36 39 42 45 4 000 4 480 4 960 5 440 5 920 6 400 18 21 24 27 30 33 36 39 42 45 ...

Page 56: ...BT C WBT Indoor water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 800 0 960 1 120 1 280 1 440 1 600 18 21 24 27 30 33 36 39 42 45 4 400 4 680 4 960 5 240 5 520 5 800 18 21 24 27 30 33 36 39 42 45 ...

Page 57: ... Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Piping Length m Input Power kW Piping Length m Capacity kW 1 000 1 020 1 040 1 060 1 080 1 100 3 4 5 6 7 8 9 10 11 12 13 14 15 4 600 4 720 4 840 4 960 5 080 5 200 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 58: ...BT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 1 600 1 620 1 640 1 660 1 680 1 700 3 4 5 6 7 8 9 10 11 12 13 14 15 4 000 4 200 4 400 4 600 4 800 5 000 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 59: ... C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Outdoor Temperature C Input Power kW Outdoor Temperature C Capacity kW 0 500 0 900 1 300 1 700 2 100 2 500 15 11 7 3 1 5 9 13 17 21 25 4 000 5 000 6 000 7 000 8 000 9 000 15 11 7 3 1 5 9 13 17 21 25 ...

Page 60: ...DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 000 1 000 2 000 3 000 4 000 5 000 16 19 22 25 28 31 34 37 40 43 3 000 4 000 5 000 6 000 7 000 8 000 16 19 22 25 28 31 34 37 40 43 ...

Page 61: ...BT C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 14 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 000 1 000 2 000 3 000 4 000 5 000 16 19 22 25 28 31 34 37 40 43 5 000 6 000 7 000 8 000 9 000 10 000 16 19 22 25 28 31 34 37 40 43 ...

Page 62: ...BT C WBT Indoor water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 000 1 000 2 000 3 000 4 000 5 000 16 19 22 25 28 31 34 37 40 43 3 000 4 000 5 000 6 000 7 000 8 000 16 19 22 25 28 31 34 37 40 43 ...

Page 63: ...C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Piping Length m Input Power kW Piping Length m Capacity kW 0 500 1 000 1 500 2 000 2 500 3 000 3 6 9 12 15 18 21 24 27 30 4 000 5 000 6 000 7 000 8 000 9 000 3 6 9 12 15 18 21 24 27 30 ...

Page 64: ...5 C DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 2 000 2 100 2 200 2 300 2 400 2 500 3 6 9 12 15 18 21 24 27 30 4 000 4 500 5 000 5 500 6 000 6 500 3 6 9 12 15 18 21 24 27 30 ...

Page 65: ...C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Outdoor Temperature C Input Power kW Outdoor Temperature C Capacity kW 1 000 1 500 2 000 2 500 3 000 3 500 15 11 7 3 1 5 9 13 17 21 25 5 000 6 000 7 000 8 000 9 000 10 000 15 11 7 3 1 5 9 13 17 21 25 ...

Page 66: ...DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 000 1 000 2 000 3 000 4 000 5 000 16 19 22 25 28 31 34 37 40 43 4 000 5 000 6 000 7 000 8 000 9 000 16 19 22 25 28 31 34 37 40 43 ...

Page 67: ...T C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 14 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 000 1 000 2 000 3 000 4 000 5 000 16 19 22 25 28 31 34 37 40 43 6 000 7 000 8 000 9 000 10 000 11 000 16 19 22 25 28 31 34 37 40 43 ...

Page 68: ...BT C WBT Indoor water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 000 1 000 2 000 3 000 4 000 5 000 16 19 22 25 28 31 34 37 40 43 4 000 5 000 6 000 7 000 8 000 9 000 16 19 22 25 28 31 34 37 40 43 ...

Page 69: ...BT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Piping Length m Input Power kW Piping Length m Capacity kW 1 000 1 500 2 000 2 500 3 000 3 500 3 6 9 12 15 18 21 24 27 30 6 000 7 000 8 000 9 000 10 000 11 000 3 6 9 12 15 18 2 1 2 4 2 7 3 0 ...

Page 70: ...5 C DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 2 600 2 700 2 800 2 900 3 000 3 100 3 6 9 12 15 18 21 24 27 30 5 000 5 500 6 000 6 500 7 000 7 500 3 6 9 12 15 18 21 24 27 30 ...

Page 71: ...4200 1220 4200 1350 4200 1500 4200 1650 4150 1860 4100 2070 7 5000 970 5000 1080 5000 1280 5000 1480 5000 1680 5000 1890 16 5000 830 5000 920 5000 1150 5000 1380 5000 1530 5000 1680 25 5000 740 5000 820 5000 1020 5000 1220 5000 1350 5000 1490 WH ADC0309H3E5 WH UD07HE5 1 Water Out C 35 40 45 50 55 Outdoor Air C Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W Capacity W In...

Page 72: ...700 900 25 5000 1430 6300 1500 5400 1060 35 4500 1670 5500 1680 5000 1330 43 3300 1530 4100 1520 4400 1530 WH ADC0309H3E5 WH UD07HE5 1 Water Out C 7 14 18 Outdoor Air C Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W 16 4800 800 7200 1160 6000 1130 25 7000 1900 8470 1780 6000 1270 35 6000 2280 6600 2480 6000 1680 43 4850 2650 6000 2820 4800 1980 WH ADC0309H3E5 WH UD09HE5...

Reviews: