background image

Installation

15

Wall-mounting

You can mount the repeater on the wall with the included wood screws and washers.

Mount the repeater on a wall (pillar) where the wood screws can be firmly fixed.

 

Drive the wood screws with washers into the wall (pillar).

Approx. 
60 mm

 

Mount onto the wall, directing the wood screws into the slots on the repeater, and slide 

the repeater down until it is secure.

L�

About 140 mm of space above the washers is required for raising the antenna.

Approx. 140 mm

2.5 – 3 mm

Wood screw 

(included)

Wall 

(Pillar)

Washer 

(included)

Important:

L�

Do not mount the repeater on walls made of plasterboard, ALC (Autoclaved Lightweight 

aerated Concrete panel), concrete block, or plywood of 18 mm or less in thickness.

Approx. 60 mm

W

all mount template

VL-FAN1BX_0329.indd   15

2006/03/29   20:23:46

Summary of Contents for VL-FAN1BX

Page 1: ...ssory unit for Panasonic Wireless Video Intercom System You must register this unit to the main monitor station before using Please read these Operating Instructions before using the unit and save for future reference Repeater Operating Instructions Model No VL FAN1BX ...

Page 2: ...hese Operating Instructions 7 Introduction Included items 8 Feature highlights 9 Preparation Location of controls 10 LIndicators 11 Installation Registering the repeater to the main monitor station REGISTRATION CANCELLATION 12 LRegistering the repeater REGISTRATION 12 LTo stop using the repeater CANCELLATION 13 Installing the repeater 14 Wall mounting 15 Help Troubleshooting 16 Cleaning 17 Resetti...

Page 3: ...ting The openings should never be blocked by placing the product on a bed sofa rug or other similar surface 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat This product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer s instruct...

Page 4: ...wing conditions occur A If smoke rises or an unaccustomed noise or smell is discharged from the unit B If metal objects have been dropped inside the unit 9 Do not make any wiring connections when the power supply is turned on 10 Never install wiring during a lightning storm 11 Do not connect the AC adaptor other than the specified voltage 12 Do not connect the AC adaptor to any terminal other than ...

Page 5: ...he power outlet L The unit should be kept away from heat sources such as heaters kitchen stoves etc It should not be placed in rooms where the temperature is less than 0 C or greater than 40 C Damp basements should also be avoided L The maximum calling distance approx 100 m may be shortened when the unit is used in the places Where there are following obstacles between this unit and the main monit...

Page 6: ...location where the unit is installed L In places where the radio signal from the main monitor station is stronger the main monitor station directly communicates with the sub monitor station without relaying through the repeater In this case the IN USE indicator may not light up Radius of radio waves from the main monitor station Radius of radio waves from the repeater In places where the radio sig...

Page 7: ...4 GHz to 2 48 GHz and the power output level can range from 0 03 to 0 175 watts Do not use the unit in health care facilities if any regulations posted in the area instruct you not to do so Hospitals or health care facilities may be using equipment that could be sensitive to external RF radio frequency energy Product names used in these Operating Instructions For plain explanation the product name...

Page 8: ... items 1 2 3 4 5 6 No Item Quantity Notes 1 Repeater 1 2 AC adaptor 1 Cord length Approx 3 m 3 AC cord 1 Cord length Approx 1 8 m 4 Wood screws 2 For wall mounting 5 Washers 2 For wall mounting 6 Registration number sticker 1 ...

Page 9: ...is installed between the main monitor station and the sub monitor station Possible obstacles L Metallic door or shutter L Heat insulator including aluminium foil L Concrete wall or wall made of galvanized iron sheet L When using the sub monitor station on the different floor or house in the same grounds where the main monitor station has been installed L Multiple walls of any sort The registration ...

Page 10: ...OGRAM button L Press to register to the main monitor station C Indicators L Show the status of this unit and the radio signal level page 11 A B C N Rear view D DC IN jack L Connect the AC adaptor E FACTORY DEFAULT RESET button L Press to reset the settings of this unit to their default settings page 17 D E Bottom view ...

Page 11: ...r station Light off This unit has not been registered to the main monitor station Green light on Shows the radio signal status from the main monitor station LTake notice of this indicator when installing page 14 Weak Strong Amber light on Red light on Red flashing Out of radio wave range so you cannot install the repeater here IN USE Green light on Repeater is relaying radio waves Light off Repeate...

Page 12: ...Lights in green DC IN jack DC plug To power outlet 100 240 V AC AC adaptor AC cord 2 Perform the registration operations using the main monitor station L Read Setting a repeater in the Operating Instructions included with the wireless video intercom system 3 Press and hold PROGRAM on the repeater for about 3 seconds within 2 minutes after completing the main monitor station operations L The STATUS...

Page 13: ... the main monitor station is not canceled To stop using the repeater CANCELLATION 1 Perform the cancellation operations using the main monitor station L Read Setting a repeater in the Operating Instructions included with the wireless video intercom system There are no repeater operations included Note L Disconnect the AC adaptor from the canceled repeater in order to avoid malfunction L You can re...

Page 14: ...gnal status Install the repeater in a location where the indicator lights in green STATUS indicator Status Lights in green Strong Able to install the repeater Lights in amber LIn places where the indicator lights in amber or red calls may be interrupted or disconnected Lights in red Weak Flashing in red Out of range Unable to install the repeater Change the location 3 Install the repeater Note L I...

Page 15: ...o the wall directing the wood screws into the slots on the repeater and slide the repeater down until it is secure L About 140 mm of space above the washers is required for raising the antenna Approx 140 mm 2 5 3 mm Wood screw included Wall Pillar Washer included Important L Do not mount the repeater on walls made of plasterboard ALC Autoclaved Lightweight aerated Concrete panel concrete block or ...

Page 16: ... the repeater to another main monitor station L You cannot register one repeater to two or more main monitor stations To register to another main monitor station another repeater is needed Can I locate the repeater in a place where the STATUS indicator does not light in green L You can install the repeater in a location where the STATUS indicator lights in amber or red but sound cuts in and out or...

Page 17: ...the default settings If you want to stop using the repeater or reset it to the default settings press FACTORY DEFAULT RESET on the bottom 1 Press FACTORY DEFAULT RESET for about 3 seconds using a pointed object such as a ball point pen L The STATUS indicator turns off 2 Perform the cancellation operations using the main monitor station L Read Setting a repeater in the Operating Instructions includ...

Page 18: ...nsumption Standby Approx 0 05 A During operation Approx 0 08 A Dimensions Approx height 27 mm x width 101 mm x depth 82 mm Approx height 69 5 mm x width 101 mm x depth 82 mm when raising the antenna Mass Weight Approx 85 g Operating environment 0 C to 40 C Up to 90 RH Relative Humidity non condensing Frequency 2 402 GHz 2 481 GHz ...

Page 19: ...ck 10 12 14 F FACTORY DEFAULT RESET button 10 17 I Indicators 10 IN USE indicator 10 11 P POWER indicator 10 11 12 14 PROGRAM button 10 12 R Registration 12 Registration number sticker 8 13 Resetting to the default settings 17 S STATUS indicator 6 10 11 12 14 T Technical data 18 Troubleshooting 16 ...

Page 20: ...nternal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic Communications Co Ltd 2006 Panasonic Communications Co Ltd All Rights Reserved PFQX2460ZA SC0406SM0 1 2 For your future reference Date of purchase Serial number found on the bottom of the unit Dealer s name and address Dealer s telephone number Attach your sales receipt here ...

Reviews: