Slide #47
Board
Result
SU
OK
SD
OK
SC
OK
Board
Result
SU
Bad
SD
OK
SC
OK
Board
Result
SU
OK
SD
Bad
SC
OK
Board
Result
SU
OK
SD
OK
SC
Bad
Board
Result
SU
Bad
SD
Bad
SC
OK
Board
Result
SU
Bad
SD
OK
SC
Bad
Board
Result
SU
OK
SD
Bad
SC
Bad
Board
Result
SU
Bad
SD
Bad
SC
Bad
A
B
C
D
A
B
C
D
Follow this procedure if the SU
board and/or the SD board are
bad while the SC board measures
OK
Follow this procedure if the SU
board and/or the SD board are
bad while the SC board is also
bad
Follow this
procedure if
only the SC
board is bad
Follow this
procedure
when all 3
boards check
OK
Replace the
SU, SD, and
SC boards
Replace the SC
board.
Go to the
next slide
Go to the
Slide #16
1.
Remove the front cabinet and check for cracks and blown pixels. (For front cabinet removal procedure go to slide 24).
2.
Check the ICs on the SU and SD boards for blown hole on the surface. (Go to slide 25 to see pictures)
3.
Perform the SU, SD, and SC boards resistance test procedure shown on slides 26~31. Match the result with one of the
following boxes (A~D) and follow the instructions at the bottom of the page.
Start Here
7 Blinks Error Code (2 of 4)
If the power LED continues to blink even after the TV is unplugged, press and hold the power
switch on the TV for a few seconds until the LED turns off.
Summary of Contents for Viera TC-P42X1
Page 5: ...Slide 5 HD boards Layout TC P42X1...
Page 6: ...Slide 6 Full HD boards Layout TC P42S1...
Page 7: ...Slide 7 Full HD Connector s Location TC P42S1...
Page 10: ...Slide 10 Shutdown Detect Block Diagram...
Page 11: ...Slide 11 HD Panel Drive SOS Detect Block Diagram TC P42X1...
Page 12: ...Slide 12 Full HD Panel Drive SOS Detect Block Diagram TC P42S1...
Page 71: ...Slide 71 The End...