n012
:
Operation control status monitor
Indicates the operation control status of the inverter. Each LED segment lights and
lights out according to the details of lighting and lighting out shown in the following table.
Normally, segment data i ~ I light.
g lights out
g lights
SW5 command status
h lights out
h lights
In operation of timer
LED segment indication
Command status
Monitor
No.
a1 lights out
a1 lights
In operation of pulse input
f lights out
f lights
SW4 command status
e lights out
e lights
SW3 command status
d lights out
d lights
SW2 command status
c lights out
c lights
SW1 command status
b lights out
b lights
Reverse run command status
a lights out
a lights
Run command status
n012
0: without command
1: with command
When command status is "in operation of timer" and parameter P45 (multi speed
function setting) is set to "3" or "4", it lights if run command is input.
When command status is "in operation of pulse input" and parameter P45 (multi speed
function setting) is set to "5" or "6", it lights if run command is input.
a
c
e
g
b
d
f
a1
c1
g1
b1
d1
f1
e1
h
h1
i
j
k
l
50