50
PRESET FREQUENCIES 2 to 8 (Parameter P32 to P38)
Used to program the speeds 2 to 8, frequencies for multi-step speed operation.
[Parameter P32 : Speed 2 frequency setting]
[Parameter P33 : Speed 3 frequency setting]
[Parameter P34 : Speed 4 frequency setting]
[Parameter P35 : Speed 5 frequency setting]
[Parameter P36 : Speed 6 frequency setting]
[Parameter P37 : Speed 7 frequency setting]
[Parameter P38 : Speed 8 frequency setting]
Data setting range
(Hz)
000 • 0.5 to 250 ("000" sets 0V stop)
Setting unit
(Hz)
0.1 (0.5 to 100Hz) 1 (100 to 250Hz)
Note)
Frequencies that exceed the maximum output frequency and the upper frequency
clamp will not be output.
2nd ACCELERATION TIME and 2nd DECELERATION TIME
(Parameters P39 and P40)
Used to set the 2nd acceleration/deceleration time selected with the 2nd characteristics
selection switch.
[Parameter P39 : 2nd acceleration time
setting]
[Parameter P40 : 2nd deceleration time setting]
Data setting range
(sec)
0.1 to 999
Setting unit
(sec)
0.1 (0.1 to 100sec) 1 (100 to 999sec)