VariCam LT Ready for Live White Paper
14
5.4. User Authentication Settings
In addition to the above, user authentication is also required to connect a VariCam LT to an ROP.
This is due to the requirement that the network account set on the VariCam LT (which can be viewed in
MENU→PERIPHERAL→NETWORK FUNC→ACCOUNT LIST) match the user information set on the ROP (which can be
viewed and set via the ROP setup software).
When using versions prior to VariCam LT Version 6.0 with the AK-HRP200G, it was necessary to change the network
settings on one of the two devices, since their default accounts were not the same.
In VariCam LT Version 6.0, the ROP default account, “username: admin, password: 12345” has been added to the default
accounts on the VariCam, enabling the devices to be connected without first making the user authentication settings.
*However, for users updating from a version prior to Version 6.0 via software update, the new account information will
only be added after the device has been initialized. After backing up your important data, use MENU→SYSTEM
SETTINGS→INITIALIZE→LOAD FACTORY DATA to initialize the device, or add the above account by following the manual
procedure.
1. Access Setup Mode on the AK-HRP200G and set each of the following items as needed.
ROP IP ADDRESS: IP address
ROP SUBNET MASK: Subnet mask
ROP DEFAULT GATEWAY: Default gateway
2. Connect the PC and ROP on the network, open the ROP setup software and open the Camera List tab.
Here, set the following items:
CONNECTION MODE: IP Mode
CAMERA TYPE: Camcorder IP
IP ADDRESS: The IP address of the camera you wish to connect (the IP address set on the VariCam LT in the
section above)
CAMERA PORT NO: 49152
After setting the above items, click the SET button to apply the changes.
*For step 1 above, the parameter can also be set using Easy IP setup software.
5.3.2 When using the AK-HRP200G
5.4.1. About User Authentication for Connections
(for Users Who Have Updated from Versions Prior to VariCam LT Version 6.0)