5. VariCam LT and ROP Connection Settings
5.1. Steps to Connect a VariCam LT with an ROP
5.2. VariCam LT Network Settings
VariCam LT network settings
ROP settings
User authentication settings
The following are the steps for connecting a VariCam LT with an ROP.
These can only be set from the VariCam LT (see 5.2).
These can be set in ROP or Easy IP setup software or I
n ROP setup software (see 5.3).
These settings are not required when using the devices under the
default settings. However, there are notes for those who have
used VariCam LT before Version 6.0
(see 5.4).
1. From MENU→PERIPHERAL→LAN PROPERTY, set each of the following items as needed.
DHCP: DHCP auto-configuration setting
IP ADDRESS: IP address
SUBNET MASK: Subnet mask
DEFAULT GATEWAY: Default gateway
PRIMARY DNS: The primary DNS server to use
SECONDARY DNS: The secondary DNS server to use
DHCP SERVER: DHCP server configuration setting
2. From MENU→PERIPHERAL→NETWORK SEL, select LAN
5.3. ROP Settings
1. From ROP MENU→ROP IP SETTING, set each of the following items as needed.
ROP IP ADDRESS: IP address
ROP SUBNET MASK: Subnet mask
ROP DEFAULT GATEWAY: Default gateway
2. From ROP MENU→CAMERA IP SETTING, set the IP address for the camera number you wish to connect to the
above IP address set on the VariCam LT and set PORT to “49152.”
3. From ROP MENU→CONNECT SETTING, set the “CONNECT MODE” for the camera number set in step 1
above to “LAN (AU).”
*For step 1 above, the parameter can also be set using Easy IP setup software.
In addition, the parameters in steps 2 and 3 can also be set using ROP setup software.
Here, we present only the basic method for connecting the VariCam LT with an ROP.
For more detail, refer to the operating guide for your VariCam LT and your ROP.
Please note in advance that the use of the AK-HRP200G requires a PC for connection settings.
5.3.1 When using the AK-HRP1000GJ/1005GJ