Operation modes
24
Operation
1) How to display the channel data
You can check channel data with an LED head connected (UV intensity level, irradiation time, and
LED head temperature).
(1) Switch to MNL mode.
1. Hold down MODE.
(2) Switch the displayed channel.
(The MNL indicator will be turned on.)
2. Press the target channel switch with an LED head
connected.
(The channel switch indicator will flash, and the
three-digit display will indicate the channel data.)
3. Press UV PWR.
(The UV intensity level and the LED head temperature
will be displayed.)
4. Press TIME.
(The irradiation time will be displayed.)
* The displayed irradiation time is the manual irradiation
time. Switch the mode or power off the controller to turn
off the time display.
*The latest setting of the UV intensity level is saved in
memory.
*You can switch the display even during irradiation. The
displayed values are saved in memory even after
power-off, and the latest displayed value will appear
again after power-on. Note that nothing will be displayed
unless a channel is selected.)
When a temperature is displayed, no unit symbol
indicator is lit. However, when a temperature warning is
issued, x100hrs is turned on.
2) How to change channel data with an LED head connected
You can change the channel data with an LED head connected.
(1) Switch to MNL mode.
1. Hold down MODE.
(2) Select the channel.
2. Press the target channel switch with an LED head
connected.
(The channel will be selected with its indicator flashing, and
the three-digit display will indicate the channel data.)
Displayed unit
Displayed value
%
UV intensity level
sec. Irradiation
time
None
LED head temperature
Warning
Displays the data of the flashing channel
You can select the channels with an LED
head connected
)
)