Operation modes
21
(3) Clear the time.
3. Press SET while the total irradiation time is displayed.
(When replacing the LED head)
(The total irradiation time display flashes.)
4. Press
T
and
S
simultaneously to reset the value to zero.
(You can set another value by using
T
and
S
.)
5. Press .
(To accept the changed value)
* Follow steps 1 to 5 above to clear/change the total
irradiation time of the other channels.
6. Hold down or MODE.
(To save the total irradiation time settings in memory and go
back to AUTO mode)
* Press MODE to cancel the change without saving it in
memory and go back to AUTO mode.
* You can simultaneously accept the entered setting and save it in memory by holding down SET.
* When connecting an LED head that has been used in other equipment, you can enter its total
irradiation time for LED life management.
Irradiation in AUTO mode
1) How to start irradiation by pressing EMISSION on the controller
Pressing the EMISSION switch will start ALL mode irradiation in PULSE start mode regardless of
the selected irradiation modes.
(1) Start irradiation.
1. Press EMISSION.
(All lit channels will start irradiation, and the EMISSION
indicator will stay on during irradiation.)
* Irradiation will stop when all channels have completed their
irradiation steps.
* While a temperature warning is issued, x100hrs stays on.
)
(2) Make an emergency stop.
2. Press EMISSION again during irradiation.
[To immediately stop irradiation of all channels (Error code
E01: Irradiation uncompleted)]
Displays the data of the flashing channel.