138
030 CED & 300 bps
1 = 75 ms
2 = 1 sec
Selects the pause interval between the CED and the
300 bps signal.
(Used when Echo Suppression is disabled.)
031 RTC = EOLx12
1 = Off (EOLx6)
2 = On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
032 V34 TX START
2400-33600bps
Selects the transmission modem start speed for V.34
communication, 33600-2400 bps.
033 V34 RX START 2400-33600bps
Selects the receiving modem start speed for V.34
communication, 33600-2400 bps.
034 V34 TX Symbol
Rate
2400-3429sr
Selects the transmission symbol rate for V.34, 3429/
3200/3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
035 V34 RX Symbol
Rate
2400-3429sr
Selects receiving symbol rate for V.34, 3429/3429/
3200/3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
036 Not Used
037 PROTOCOL
DISPLAY
1 = Off (not displayed)
2 = On (displayed)
Selects whether to display the modem speed during
communication.
Press “V” or “/\ “ to display.
038 Not Used
039 FLASH TIME
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
040 E/F TIME
(Except for USA
and Canada)
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
041 PAUSE TIME
1 = 1 sec.
~
10 = 10 sec.
Selects the pause interval from 1 sec. ~ 10 sec. for
dialing through a switchboard or for international
calls.
042 Not Used
043 REDIAL
INTERVAL
0 = no waiting
~
15 = 15 minutes
Selects the redial interval from 0 to 15 minutes in 1
minute steps.
044 REDIAL COUNT 0 = no redial
~
15 = 15 times
Selects the redial count from 0 to 15 times in 1 step
intervals.
Note:
In order to comply with the requirements TBR21 in
the EC destinations, do not select 15 times.
045 RING DETECT
COUNT
1 = 1 ring
~
9 = 9 rings
Selects the ring detection count from 1 to 9 rings in 1
ring step intervals.
046 ON-HOOK TIME 0 = 0 sec.
~
90 = 90 sec.
Selects the on-hook time between sequential
communication calls in 1 second step intervals.
047 RESPONSE
WAIT
1 = 1 sec.
~
90 = 90 sec.
Selects the waiting interval for the response after
completing the dialing.
048
049
Not Used
050 RING DETECT
MODE
1 = Normal
2 = Rough
Selects the quality of ringer detection. Use if the line
signal is out of regulation, set to "Rough" so that the
unit may detect the ringing signals.
Function Parameter Table
No.
Parameter
Selections
Function