1-6
1
1
Single-Type
High Static Pressure Ducted Type S-250PE1E8 / U-250PE1E8
–
57
Indoor unit
12.7 (1 / 2)
25.4 (1)
–
Indoor unit
467 (18-12 / 32)
1,428 (56-7 / 32)
1,230 (48-14 / 32)
614 (24-11 / 64)
1,536 (60-15 / 32)
1,339 (52-23 / 32)
120 (256)
144 (317)
1.268 (44.8)
Outdoor unit
1526 (60-5 / 64)
940 (37-1 / 64)
340 (13-25 / 64)
1676 (65-63 / 64)
1076 (42-23 / 64)
420 (16-17 / 32)
128 (282)
138 (304)
0.757 (26.7)
NOTE
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
*1 There are two types of supplied tubings. The one tubing port ø19.05 (flare process) is connected to the flared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):
Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):
Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):
Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):
Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
MODEL No.
Indoor Unit
Outdoor Unit
POWER SOURCE
Indoor Unit
Outdoor Unit
PERFORMANCE
Capacity [min~max]
kW
BTU / h
Air circulation (Hi / Me / Lo)
m
3
/ h
Liters / h
Moisture removal (High)
Pa (mmAq)
External static pressure (High)
ELECTRICAL RATINGS
V
Voltage ratings
V
Available voltage range
A
Running amperes*
A
Max–Running amperes**
kW
Power input
W / W
C.O.P
A
Max.Starting amperes
FEATURES
Controls / Thermostat control
Timer
Fan speeds Indoor / Outdoor
Airflow direction (Indoor)
Air filter
Remote controller (Option)
Refrigerant control
Drain pump (Drain connection)
Compressor
Operation sound
Indoor - Hi / Me / Lo
dB-A
dB-A
Outdoor - Hi
Color
(Approximate value)
Indoor
Outdoor
REFRIGERANT TUBING
Limit of tubing length
Limit of tubing length at shipment
Limit of elevation difference
between the two units
m (ft.)
m (ft.)
m (ft.)
Refrigerant tube
outer diameter
Liquid tube
mm (in.)
Gas tube
mm (in.)
k
g
Refrigerant amount at shipment
DIMENSIONS & WEIGHT
Unit dimensions
Height
mm (in.)
Width
mm (in.)
Depth
mm (in.)
Package dimensions
Height
mm (in.)
Width
mm (in.)
Depth
mm (in.)
k
g
(lb.)
k
g
(lb.)
Net weight
Shipping weight
m
Shipping volume
3
(cu.ft)
25.0 [6.0~28.0]
85,300 [20,500~95,500]
13.9
Cooling
28.0 [6.0~31.5]
95,500 [20,500~107,500]
–
Heating
14.8
–
9.55
2.62
–
400
12.3
–
8.26
3.39
–
415
12.6
–
8.20
3.41
–
400
13.1
–
8.14
3.44
–
380
14.3
–
9.61
2.60
–
415
15.3
–
9.49
2.63
–
380
S-250PE1E8
U-250PE1E8
4,320 / 4,200 / 3,960
216 (22): at shipment 235 (24): using the booster cable
ON / OFF 72-hours
–
Field supply
–
51 / 50 / 49
220-230-240V, 50/60Hz, single-phase
380-400-415V, 50/60Hz, 3-phase
342~456(Outdoor) 198~264(Indoor)
Microprocessor / I.C.thermostat
3 and Automatic control / Variable
Wired: CZ-RTC2 / Wireless: CZ-RWSC2
25A Male screw (No Drain Pump)
Rotary
Munsell 1Y 8.5 / 0.5
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
100 (328)
5~30(16~98)
58
Outdoor unit
12.7 (1 / 2)
R410A - 6.5
25.4 (1)*
1
1
1-2. Major Component Specifications
(A) Indoor Units
High Static Pressure Ducted Type S-200PE2E5
MODEL No.
Source
Controller P.C.B. Ass'y
Fan (Number...diameter)
mm
Fan motor
W
Model...Nominal output
Power source
rpm
No. of pole...r.p.m. (230V, High)
Coil resistance
(Ambient temperature 20°C)
Ω
VAC, µF
Run capacitor
Electronic expansion valve
Coil
Coil resistance (at 20°C)
Ω
Valve body
Heat exchanger
Coil
mm
Rows...fin pitch
m
Face area
2
S-200PE2E5
220 - 230 - 240V, single-phase, 50Hz
CR-280ME2E5
SIROCCO (2...ø250)
DMUB6D1AC...560W
DMUB6D2AC...560W
100 - 391 VDC
8P...860
–
–
–
–
–
Aluminium plate fin / Copper tube
3...1.8
0.648
Sec1.indd 6