Single-Type
High Static Pressure Ducted Type S-200PE1E8A / U-200PE1E8
MODEL No.
POWER SOURCE
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
PERFORMANCE
Capacity [min~max]
Air circulation (Hi / Me / Lo)
Heating
21.8 [6.0~22.4]
74,400 [20,500~76,400]
–
Cooling
20.0 [6.0~22.4]
68,200 [20,500~76,400]
11.1
Moisture removal (High)
kW
BTU / h
m
3
/ h
Liters / h
Pa (mmAq)
External static pressure (High)
ELECTRICAL RATINGS
Voltage ratings
Available voltage range
Running amperes*
Max–Running amperes**
Power input
C.O.P
415
9.3
–
6.21
3.51
–
400
9.5
–
6.15
3.54B
–
380
9.8
–
6.09
3.58
–
415
11.5
–
7.70
2.60
–
400
11.8
–
7.64
2.62D
–
380
12.2
–
7.58
2.64
–
V
V
A
A
kW
W / W
A
Max.Starting amperes
FEATURES
Controls / Thermostat control
Timer
Fan speeds Indoor / Outdoor
Airflow direction (Indoor)
Air filter
Remote controller (Option)
Refrigerant control
Drain pump (Drain connection)
Compressor
Operation sound
Indoor - Hi / Me / Lo
dB-A
dB-A
57
57
Outdoor - Hi
Color
(Approximate value)
Indoor
342~456(Outdoor) 198~264(Indoor)
Microprocessor / I.C.thermostat
ON / OFF 72-hours
3 and Automatic control / Variable
–
Field supply
Wired: CZ-RTC2 / Wireless: CZ-RWSC2
–
25A Male screw (No Drain Pump)
Rotary
51 / 50 / 49
–
Munsell 1Y 8.5 / 0.5
Outdoor
REFRIGERANT TUBING
Limit of tubing length
Limit of tubing length at shipment
Limit of elevation difference
between the two units
100 (328)
5~30(16~98)
Outdoor unit is higher than indoor unit: 30 (98)
Outdoor unit is lower than indoor unit: 30 (98)
Refrigerant tube
outer diameter
Liquid tube
Gas tube
m (ft.)
m (ft.)
m (ft.)
mm (in.)
mm (in.)
mm (in.)
mm (in.)
mm (in.)
k
g
Refrigerant amount at shipment
DIMENSIONS & WEIGHT
Unit dimensions
Height
Width
Depth
Package dimensions
Height
Width
Depth
mm (in.)
mm (in.)
mm (in.)
k
g
(lb.)
k
g
(lb.)
Net weight
Shipping weight
m
3
(cu.ft)
Shipping volume
1
–
Indoor unit
9.52 (3 / 8)
25.4 (1)*
Indoor unit
479 (18-55 / 64)
1,428 (56-7 / 32)
1,230 (48-27 / 64)
619 (24-3 / 8)
1,536 (60-15 / 32)
1,339 (52-23 / 32)
120 (265)
144 (317)
1.273 (44.9)
1
Outdoor unit
9.52 (3 / 8)
25.4 (1)*
R410A - 5.3
Outdoor unit
1526 (60-5 / 64)
940 (37-1 / 64)
340 (13-25 / 64)
1676 (65-63 / 64)
1076 (42-23 / 64)
420 (16-17 / 32)
118 (260)
128 (282)
0.757 (26.7)
NOTE
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
*1 There are two types of supplied tubings. The one tubing port ø19.05 (flare process) is connected to the flared connection of the gas port
side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length.
Then make a brazing connection to the main tubing (ø25.4).
Cooling:
Rating conditions (*):
Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):
Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*):
Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**):
Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
4,320 / 4,200 / 3,960
216 (22): at shipment 235 (24): using the booster cable
U-200PE1E8
220-230-240V, 50Hz, single-phase
380-400-415V, 50/60Hz, 3-phase
S-200PE1E8A
Sec1.indd 4
2014/11/07 10:27:49