Pin No.
Signal Name
1
NC (Not connected)
2
RXD
3
TXD
4
Non Use
5
GND (Ground)
6
Non Use
7
RTS
Shorted in this set
8
CTS
9
NC (Not connected)
These signal names are those of computer
specifications.
Communication parameters
Signal level: RS-232C compliant
Synchronization method: Asynchronous
Baud rate: 9 600 bps
Parity: None
Character length: 8 bits
Stop bit: 1 bit
Flow control: None
Basic format for control data
The transmission of control data from the computer
starts with a STX signal, followed by the command, the
parameters, and lastly an ETX signal in that order. Add
parameters as required according to control details.
STX
ETX
C1 C2
P1 P2 P3 P4 P5
C3
:
3-Character Parameter(s)
Command
(3 Bytes)
Command Parameter
Control Details
PON
None
Power ON
POF
None
Power OFF
AVL
***
Volume 000-100
AMT
0
Audio MUTE OFF
1
Audio MUTE ON
IMS
None
Input Select (toggle)
HM1
HDMI1
HM2
HDMI2
HM3
HDMI3
HM4
HDMI4
DP1
DisplayPort
SL1
SLOT
PC1
PC
UC1
USB-C
WD1
Wireless Display
DAM
AUTO
Aspect mode select
Auto
FULL
Full
1609
16:9
1409
14:9
0403
4:3
CINM
Cinema
Note:
•
If multiple commands are transmitted, be sure
to wait for the response for the first command
to come from this unit before sending the next
command.
•
If an incorrect command is sent by mistake, this
unit will send an “ER401” command back to the
computer.
•
When sending a command which does not
require parameter, a colon (:) is not needed.
•
Consult your local Panasonic dealer for detail
instructions on command usage.
For more details, visit the following web site.
https://panasonic.net/cns/prodisplays/
Control Command via
LAN
Connection Method
1. Obtain the display’s IP address and the
Command port (Default is 1024), and request
connection to the display.
The IP address and the port number can be
obtained from the following menus.
•• IP address:
Start
Colon
End