9
English
Precautions for use
Cautions when installing
Do not set up the Display outdoors.
•
The Display is designed for indoor use.
Install this unit at a location which can support the
weight of the unit.
•
Use the installation bracket that conforms to VESA
standards
Environmental temperature to use this unit
•
When using the unit where it is below 1 400 m
(4 593 ft) above sea level: 0 °C to 40 °C (32 °F to
104 °F)
•
When using the unit at high altitudes (1 400 m
(4 593 ft) and higher and below 2 800 m (9 186 ft)
above sea level): 0 °C to 35 °C (32 °F to 95 °F)
Do not install the unit where it is 2 800 m (9 186 ft)
and higher above sea level.
•
Failure to do so may shorten the life of the internal
parts and result in malfunctions.
We are not responsible for any product damage, etc.
caused by failures in the installation environment
even during the warranty period.
Do not place the display where it may be affected by
salt or corrosive gas.
•
Failure to do so may shorten the life of the internal
parts and result in malfunctions due to corrosion.
Required space for ventilation
•
When using the Pedestal (optional accessory), leave
a space of 10 cm (3
15/16
”) or more at the top, left and
right, and 5 cm (1
31/32
”) or more at the rear, and also
keep the space between the bottom of the display
and the floor surface.
If using some other setting-up method (wall-hanging,
etc.), follow the manual of it. (If there is no specific
indication of installation dimension in the installation
manual, leave a space of 10 cm (3
15/16
”) or more at
the top, bottom, left and right, and 5 cm (1
31/32
”) or
more at the rear.)
Minimum distance:
a
a
b a: 10 cm
(3
15/16
”)
b: 5 cm
(1
31/32
”)
a
•
Operation of this unit is guaranteed up to an ambient
temperature of 40 °C (104 °F). When installing the
unit in a case or chassis, be sure to provide adequate
ventilation with a cooling fan or ventilation hole so
that the surrounding temperature (inside the case or
chassis) including the temperature of the front surface
of the liquid crystal panel can be kept at 40 °C
(104 °F) or less.
About the screws used when using a wall hanging
bracket that conforms to VESA standards
Inch
model
Screw pitch for
installation
Depth of
screw
hole
Screw
(quantity)
75
400 mm × 400 mm
25 mm
M6 (4)
Be careful of the movable structure of the power
indicator and remote control sensor.
•
As factory default, the power indicator and remote
control sensor are stored in the main unit. In
normal cases, pull the remote control sensor box
from the end face of the unit until it gets locked at
the designated position. Depending on the setup
condition such as when using the multi display, store
the remote control sensor in the main unit. (see page
21)
Depending on the temperature or humidity
conditions, uneven brightness may be observed.
This is not a malfunction.
•
This unevenness will disappear while applying current
continuously. If not, consult the distributor.
Summary of Contents for TH-75BQE1
Page 27: ...27 English Customer Service ...