Error
Code
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
F500
DSC error
DSC (IC8251) stops in the occurrence of
servo error (startup, focus error, etc.)
Press [
] on main
unit for next error.
F501
DSC not Ready error
DSC-system computer communication
error (Communication failure caused by
idling of DSC)
Press [
] on main
unit for next error.
F502
DSC Time out error
Similar as F500
Press [
] on main
unit for next error.
F503
DSC communication
Failure
Communication
error
(result
error
occurred
although
communication
command was sent)
Press [
] on main
unit for next error.
F504
Abnormal adjusting DSC
data slice offset
Press [
] on main
unit for next error.
F505
DSC Attention error
Similar as F500
Press [
] on main
unit for next error.
F506
Invalid media
Disc is flipped over, TOC unreadable,
incompatible disc media
Press [
] on main
unit for next error.
F600
Access failure to
management information
caused by demodulation
error
Operation stopped because navigation
data is not accessible caused by the
demodulation defect
Press [
] on main
unit for next error.
F601
Indeterminate sector ID
requested
Operation
stopped
caused
by
the
request to access abnormal ID data
Press [
] on main
unit for next error.
F602
Access failure to LEAD-
IN caused by
demodulation error
LEAD IN data unreadable
Press [
] on main
unit for next error.
F603
Access failure to
KEYDET caused by
demodulation error
Access failure to CSS data of disc
Press [
] on main
unit for next error.
F610
ODC abnormality
No permission for command execution
Press [
] on main
unit for next error.
F611
No CRC OK for a
specific time (CD)
Access failure to seek address in CD
series
Press [
] on main
unit for next error.
F612
No CRC OK for a
specific time (DVD)
Access failure to ID data in DVD series
Press [
] on main
unit for next error.
F620
Laser safeguard: high
temperature condition
High temperature of the laser guide unit
(OPU unit)
Press [
] on main
unit for next error.
F621
Laser safeguard: circuit
failure condition
Circuitry failure of the laser guide unit
(OPU unit)
Press [
] on main
unit for next error.
F700
MBX overflow
When replying message to disc manager
Press [
] on main
unit for next error.
F701
Message command
does not end
Next message is sent before replying to
disc manager
Press [
] on main
unit for next error.
F702
Message command
changes
Message is changed before it is sent as
a reply to disc manager
Press [
] on main
unit for next error.
31
SA-VK950GC / SA-VK950GS / SA-VK950GCS / SA-VK950GCT
30
manual de servicio SC-TM910DVD