TROUBLESHOOTING
If your air conditioner does not work properly, fi rst check the following points before requesting service. If it still does not work
properly, contact your dealer or a service center.
INDOOR UNIT
Symptom
Cause
Noise
Sound like streaming water during
operation or after operation.
• Sound of refrigerant liquid fl owing inside unit.
• Sound of drainage water through drain pipe.
Cracking noise during operation or
when operation stops.
Cracking sound due to temperature changes of parts.
Odor
Discharged air is smelled during
operation.
Indoor odor components, cigarette odor and cosmetic odor accumulated
in the air conditioner and its air is discharged.
Unit inside is dusty. Consult your dealer.
Dewdrop
Dewdrop gets accumulated near air
discharge during operation.
Indoor moisture is cooled by cool wind and accumulated by dewdrop.
Fog
Fog occurs during operation in
cooling mode.
(Places where large amounts of oil
mist exist at restaurants.)
• Cleaning is necessary because unit inside (heat exchanger) is dirty.
Consult your dealer as technical engineering is required.
• During defrost operation.
Fan is rotating for a while even though operation
stops.
• Fan rotating makes operation smoothly.
• Fan may sometimes rotates because of drying heat exchanger due to
settings.
Wind-direction changes while operating.
Wind-direction setting cannot be made.
Wind-direction cannot be changed.
• When air discharge temperature is low or during defrost operation,
horizontal wind fl ow is made automatically.
• Flap position is occasionally set up individually.
When wind-direction is changed, fl ap operates
several times and stops at designated position.
When wind-direction is changed, fl ap operates after searching for
standard position.
Dust
Dust accumulation inside indoor unit is discharged.
At the initial high-speed operation, the fan may
sometimes rotate faster (for 3 to 30 minutes) than
the setting speed.
This is for operation check in order to confi rm whether the fan motor
rotation is within use range.
OUTDOOR UNIT
Symptom
Cause
No
operation
When power is turned ON instantly.
Operation is not activated for the fi rst approx. 3 minutes because
compressor protection circuit is activated.
When operation is stopped and
resumed immediately.
Noise
Noise often occurs in heating mode.
During defrost operation.
Steam
Steam often occurs in heating mode.
When stopped by remote controller, outdoor unit fan
is sometimes operating for a while even though
outdoor compressor is stopped.
Fan rotating makes operation smoothly.
Summary of Contents for S-22MK2E5A
Page 31: ...31 1 2 3 5 ON ON...
Page 32: ...32 ELCB ON OFF 1 5...
Page 33: ...33...
Page 35: ...35 OP EN CL OS E CL OS E OP EN Y2 4 60x60 K2...
Page 37: ...37 Y2 K2 FLAP FLAP FLAP FLAP FLAP...
Page 38: ...38 4 Y2 Y2 K2 FLAP FLAP A A A B...
Page 39: ...39 UNIT UNIT 1 1 1 2 1 3 1 8 1 1 1 2 1 3 2 4 1 4 2 1...
Page 40: ...40 DRY LO 15 C DRY STANDBY 1 2 1 2 3...
Page 41: ...41 pH7 40 C 1 2...
Page 42: ...42 3 30 3...
Page 43: ...43 ON OFF E F H L P...