11.10.5 INDOOR UNIT DRAIN PIPING
•
Drain piping must have down-slope (1/50 to
1/100); be sure not to provide up-and-down slope
to prevent reversal flow.
•
During drain piping connection, be careful not to
exert extra force on the drain port at the indoor
unit.
•
The outside diameter of the drain connection at
the indoor unit is 16 mm.
Piping material: Polyvinyl chloride pipe VP-16 and
pipe fittings.
•
Be sure to perform heat insulation on the drain
piping.
Heat insulation material: Polyethylene foam with
thickness more than 8 mm (local supply).
Upward routing
Pipe clamp
Indoor
unit
Trap
Down-slope
11.10.6 HEAT
INSULATION
Caution
Be sure to perform heat insulation on the drain, liquid and gas piping. Imperfection in heat insulation work leads to water
leakage.
1. Use the heat insulation material for the refrigerant piping which has an excellent heat-resistance (over 120°C).
Overlap with heat
insulator for piping.
Indoor
unit
Band
(Accessory)
Heat insulator
for piping
(Local supply)
Heat insulator
(Accessory)
Hose clip (Accessory)
Heat insulator (Local
supply) (The thickness
must be at least 8 mm.)
Flexible hose with
heat insulator
(Accessory)
PVC pipe
(O.D. ø16)
(Local supply)
To be glued
It may be required to take off this part for checking
or servicing the drain up motor. Please do not glue.
Make sure that there is no clearance here.
2. Precautions in high humidity circumstance.
This air conditioner has been tested according to the “JIS Standard Conditions with Mist” and have been
confirmed that there are no faults. However, if it is operated for a long time in high humid atmosphere (dew point
temperature: more than 23°C), water drops are liable to fall. In this case, add heat insulation material according
to the following procedure:
•
Heat insulation material to be prepared…
Adiabatic glass wool with thickness 10 to 20
mm.
•
Stick glass wool on all air conditioners that are
located in ceiling atmosphere.
•
In addition to the normal heat insulation
(thickness: more than 8 mm) for refrigerant
piping (gas piping: thick piping) and drain
piping, add a further of 10 mm to 30 mm
thickness material.
Pipe down
Indoor
unit
Pipe
Putty
Trap
Incision
Drain pipe
✳
Put the incision at the trap part of the heat insulator
(for water drain)
Wall seal
•
When the outdoor unit is installed on a higher position than the indoor unit, install the trap so as not to instill
rain water into the wall by transmitting in piping.
•
Stuff the space among piping, the electric wire, and the drain hose with “Putty” and seal the penetration wall
hole.
Make sure that rain water do not instill into the wall.
Summary of Contents for S-22KA1E5S
Page 45: ...45 4 1 2 S 56KA1E5 S 63KA1E5 S 71KA1E5...
Page 47: ...47 4 3 95 x 95 Cassette Type Indoor Unit 4 3 1 S 63UA1E5 S 71UA1E5 S 90UA1E5...
Page 48: ...48 4 3 2 S 100UA1E5 S 125UA1E5...
Page 50: ...50 4 5 Low Static Pressure Hide Away Type Indoor Unit 4 5 1 S 45MA1E5 S 56MA1E5...
Page 51: ...51 4 5 2 S 63MA1E5 S 71MA1E5 S 90MA1E5...
Page 52: ...52 4 5 3 S 100MA1E5 S 125MA1E5...
Page 53: ...53 4 6 Outdoor Unit 4 6 1 U 8EA1E8 U 10EA1E5...
Page 54: ...54 5 Refrigeration Cycle Diagram...
Page 58: ...58 7 Wiring Connection Diagram 7 1 Wall Mounted Type Indoor Unit KA1E5 Series...
Page 59: ...59 7 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series...
Page 60: ...60 7 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series...
Page 61: ...61 7 4 Slim Hide Away Type Indoor Unit NA1E5 Series...
Page 62: ...62 7 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series...
Page 63: ...63 7 6 Outdoor Unit EA1E8 Series...
Page 64: ...64 8 Electronic Circuit Diagram 8 1 Wall Mounted Type Indoor Unit KA1E5 Series...
Page 65: ...65...
Page 66: ...66 8 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series...
Page 67: ...67...
Page 68: ...68 8 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series...
Page 69: ...69...
Page 70: ...70 8 4 Slim Hide Away Type Indoor Unit NA1E5 Series...
Page 71: ...71...
Page 72: ...72 8 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series...
Page 73: ...73...
Page 74: ...74 8 6 Outdoor Unit EA1E8 Series...
Page 75: ...75...
Page 77: ...77 9 1 3 Receiver PCB CN DISP 9 1 4 Error Code Display PCB CN CODE...
Page 82: ...82 9 6 2 Inverter PCB CN AC CN RY2 CN RY1 CN FM2 CN COM FG DCN CN FM1 DCP W V U...
Page 231: ...231 19 Operation Range...
Page 233: ...233 21 Outdoor Unit Cooling Heating Capacity and Power Input 21 1 U 8EA1E8...
Page 234: ...234...
Page 235: ...235 21 2 U 10EA1E8...
Page 236: ...236...
Page 302: ...302 27 8 Outdoor Unit U 10EA1E8...