34
Gas side
mm (inch)
12.70 (1/2)
15.88 (5/8)
Diameter
Liquid side
mm (inch)
6.35 (1/4)
9.52 (3/8)
Piping
Max Length
m (ft)
15.0 (49.20)
15.0 (49.20)
External diameter
mm
32
32
Drain hose
Length mm
180
180
Fin material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
3 x 12 x 18
3 x 12 x 18
Indoor Heat
Exchanger
Size (W x H x L)
mm
860 x 252 x 38.1
860 x 252 x 38.1
Material
PP
PP
Air Filter
Type
-
-
Power Supply
Indoor Power Supply
Indoor Power Supply
Length m
(ft)
-
-
Power cord
Core x Diameter
mm
2
-
-
Thermostat
Electronic Control
Electronic Control
Maximum °C
32
32
Cool
Minimum °C
21
21
Maximum °C
27
27
Indoor Operation
Range
Heat
Minimum °C
16
16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68.0°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, input power and COP measured at 230V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for future improvement.
Summary of Contents for S-22KA1E5
Page 4: ...4 23 6 Heating 430 24 Exploded View and Replacement Parts List451 24 1 Indoor Unit 451...
Page 12: ...12...
Page 40: ...40 4 1 2 S 56KA1E5 S 63KA1E5 S 71KA1E5...
Page 42: ...42 4 3 95 x 95 Cassette Type Indoor Unit 4 3 1 S 63UA1E5 S 71UA1E5 S 90UA1E5...
Page 44: ...44 4 5 Low Static Pressure Hide Away Type Indoor Unit 4 5 1 S 45MA1E5 S 56MA1E5...
Page 45: ...45 4 5 2 S 63MA1E5 S 71MA1E5 S 90MA1E5...
Page 51: ...51 7 Wiring Connection Diagram 7 1 Wall Mounted Type Indoor Unit KA1E5 Series...
Page 52: ...52 7 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series...
Page 53: ...53 7 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series...
Page 54: ...54 7 4 Slim Hide Away Type Indoor Unit NA1E5 Series...
Page 55: ...55 7 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series...
Page 56: ...56 7 6 Outdoor Unit LA1E5 Series...
Page 57: ...57 8 Electronic Circuit Diagram 8 1 Wall Mounted Type Indoor Unit KA1E5 Series...
Page 58: ...58...
Page 59: ...59 8 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series...
Page 60: ...60...
Page 61: ...61 8 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series...
Page 62: ...62...
Page 63: ...63 8 4 Slim Hide Away Type Indoor Unit NA1E5 Series...
Page 64: ...64...
Page 65: ...65 8 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series...
Page 66: ...66...
Page 67: ...67 8 6 Outdoor Unit LA1E5 Series...
Page 68: ...68...
Page 70: ...70 9 1 3 Receiver PCB CN DISP 9 1 4 Error Code Display PCB CN CODE...
Page 74: ...74 9 6 Outdoor Unit LA1E5 Series 9 6 1 Main PCB...
Page 76: ...76 9 6 3 Capacitor PCB DCN IN DCN OUT DCP IN DCP OUT...
Page 195: ...195...
Page 201: ...201...