channel button (05) on the remote control to select "H PHASE".
3. Press the VOL. UP/DOWN button on the remote control until the
SHIFT quantity of the OVER SCAN on right and left becomes
minimum.
13.2.13. VERTICAL SHIFT
1. Receive the monoscope pattern.
2. Activate the adjustment mode display of
Fig. 1-1
and press the
channel button (07) on the remote control to select "V SHIFT".
3. Check if the step No. of V. SHIFT is "01".
4. Adjust the VR402 until the horizontal line becomes fit to notch of
the shadow mask.
13.2.14. VERTICAL SIZE
1. Receive the monoscope pattern.
2. Activate the adjustment mode display of
Fig. 1-1
and press the
channel button (06) on the remote control to select "V SIZE".
3. Press the VOL. UP/DOWN button on the remote control until the
SHIFT quantity of the OVER SCAN on upside and downside
becomes minimum.
4. Receive a broadcast and check if the picture is normal.
13.2.15. OSD HORIZONTAL
1. Activate the adjustment mode display of
Fig. 1-1
.
2. Press the VOL. UP/DOWN button on the remote control until the
difference of A and B becomes minimum. (Refer to
Fig. 2-4
)
Fig. 2-4
13.2.16. SUB SHARPNESS
1. Activate the adjustment mode display of
Fig. 1-1
and press the
51