12.1.3. CONFIRMATION OF PLAYBACK TORQUE AND BACK TENSION TORQUE
DURING PLAYBACK
1. Load a video tape (T-120) recorded in standard speed mode. Set
the unit to the PLAY mode.
2. Install the tentelometer as shown in
Fig. 1-3
. Confirm that the
meter indicates 20 ± 2gf in the beginning of playback.
- USING A CASSETTE TYPE TORQUE TAPE (JG100A)
1. After confirmation and adjustment of Tension Post position (Refer
to item 1-2), load the cassette type torque tape (JG100A) and set to
the PLAY mode.
2. Confirm that the right meter of the torque tape indicates 50~90gf
cm during playback in SP mode.
3. Confirm that the left meter of the torque tape indicates 25~40gf cm
during playback in SP mode.
Fig. 1-3
12.1.4. CONFIRMATION OF VSR TORQUE
1. Install the Torque Gauge (JG002F) and Adapter (JG002B) on the S
Reel. Set to the Picture Search (Rewind) mode. (Refer to
Fig. 1-4-B
)
2. Then, confirm that it indicates 120~180gf cm.
NOTE
Install the Torque Gauge on the reel disk firmly. Press the REW button to turn the reel disk.
38