Chapter 7
Appendix — Technical information
184 - ENGLISH
PJLink security authentication
The password used for PJLink is the same as that of the password set for web control.
When using the projector without security authentication, do not set a password for web control.
f
For specifications related to PJLink, visit the website of Japan Business Machine and Information System
Industries Association.
URL http://pjlink.jbmia.or.jp/english/
Using Art-Net function
Since the network function of the projector supports the Art-Net function, you can control the projector settings
with the DMX controller and application software using the Art-Net protocol.
Channel definition
The following table lists the channel definitions used for controlling the projector with the Art-Net function.
Channel settings can be switched using the [NETWORK] menu
→
[Art-Net CHANNEL SETTING] (
x
page 152).
The control details assigned to each channel are listed in the following table.
f
Channel assignment for [USER] is in factory default setting. Assignment can be changed.
Channel
Control details
[2]
[USER]
[1]
CHANNEL1
LIGHT OUTPUT
LIGHT OUTPUT
SHUTTER
CHANNEL2
INPUT SELECT
INPUT SELECT
INPUT SELECT
CHANNEL3
LENS POSITION
LENS POSITION
LENS FUNCTION SELECT
CHANNEL4
LENS H SHIFT
LENS H SHIFT
LENS CONTROL
CHANNEL5
LENS V SHIFT
LENS V SHIFT
POWER
CHANNEL6
LENS FOCUS
LENS FOCUS
LIGHT OUTPUT
CHANNEL7
LENS ZOOM
LENS ZOOM
ENABLE/DISABLE
CHANNEL8
POWER
POWER
FADE-IN
CHANNEL9
GEOMETRY
GEOMETRY
FADE-OUT
CHANNEL10
CUSTOM MASKING
*1
CUSTOM MASKING
*1
CUSTOM MASKING
*1
CHANNEL11
ENABLE/DISABLE
ENABLE/DISABLE
GEOMETRY
CHANNEL12
NONE
NONE
NONE
*1
For PT-RZ770, PT-RZ660. The setting for PT-RW730 or PT-RW620 is “NONE”.
Control details
r
LIGHT OUTPUT
This can be set in 256 steps between 100 % and 0 %.
Performance
Parameter
Default value
100 %
0
0
…
…
0 %
255