INF - 13
Example. Asking command on power condition "QPW"
1. Connection to projector
IP = 192.168.0.8 port = 1024
2. Response received
Response = "NTCONTROL 1 1aa6c14e" + (CR)
1aa6c14e = 8 byte random value
3. Hash data is created from "admin1 : panasonic : 1aa6c14e" by MD5 algorism
admin1 = Administrator user name
panasonic = "admin1" password
Hash value = "01466bc27ed8c0b7e607471580c55953"
4. Data transmission
Transmitting data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
5. Receiving response
Receiving data = "00000" + (CR)
6. Close the communication with projector
4. 2. 3. WEB Control Admin without password setting (Non protect mode)
4. 2. 3. 1. Connecting procedure
1. Get the projector IP address and port number (default is 1024) and request the connection to the projector.
IP address and the port number can be get in menu of projector.
Get it in Main menu, "Network" -> "Network Status"
Get it in Main menu "Network" -> "Network Control" -> "Command Port"
2. Receive the response from projector
Responding data
Mode: 0 = Non protect mode
4. 2. 3. 2. Command transmission
Send the command with the style below.
Transmission data
Receiving data
Error response
“ERR1”
Command format error
“ERR2”
Out of parameter
“ERR3”
Busy or unavailable time
“ERR4”
Timeout or unavailable time
“ERR5”
Data length error
“ERRA”
Invalid password
Example. Asking command on power condition "QPW"
1. Connecting to projector
IP = 192.168.0.8 port = 1024
2. Receiving response
Response = "NTCONTROL 0 " + (CR)
3. Data transmission
Transmitting data = "00QPW" + (CR)
4. Receiving response
Receiving data = "00000" + (CR)
5. Close the connection to projector
‘0’
‘0’
Control command
(CR)
1 byte
1 byte
Non defined length
1 byte
Error massage <4 bytes>
1 byte
1 byte
Non defined length
1 byte
0x30
0x30
(ASCII character)
0x0d
Header
Data
0x30
0x30
(ASCII character)
0x0d
Header
Data
Terminal symbol
‘0’
‘0’
Control command
(CR)
IP Address:
Port number:
Data
Space
Terminal symbol
Mode
(CR)
0x0d
1 byte
(ASCII character)
0x20
0x30
9 bytes
1 byte
1 byte
“NTCONTROL”
‘ ’
‘0’
(CR)
0x0d
Terminal symbol <1 byte>
(CR)
0x0d
Terminal symbol
(CR)
0x0d
(CR)
0x0d
(CR)
0x0d
(CR)
0x0d
Summary of Contents for PT-RZ470 Series
Page 6: ...6 2 Specifications...
Page 7: ...7...
Page 9: ...INF 2 1 The name of each part 1 1 Projector body 1 2 Control panel...
Page 10: ...INF 3 1 3 Connecting terminals 1 4 Remote control...
Page 11: ...INF 4 2 OSD Menu Navigation...
Page 12: ...INF 5...
Page 13: ...INF 6...
Page 26: ...INF 19 5 Select Log SYSTEM and click Get button 6 Log is displayed...
Page 84: ......