Chapter 4
Settings — [PROJECTOR SETUP] menu
ENGLISH - 175
[DETAILED INFORMATION]
[INPUT]
Displays the input terminal used for the projected image.
[UPPER LEFT INPUT],
[UPPER RIGHT INPUT],
[LOWER LEFT INPUT],
[LOWER RIGHT INPUT]
Displays the input terminal corresponding to each screen while in
the four-screen display mode.
[SIGNAL FORMAT]
Displays the format of the input signal.
[SIGNAL FREQUENCY]
Displays the frequency of the input signal.
[SCAN TYPE]
Displays the scan type of the input signal.
[TOTAL DOTS]
Displays the total dot count of the input signal.
[DISPLAY DOTS]
Displays the number of input signal display dots.
[TOTAL LINES]
Displays the total line count of the input signal.
[DISPLAY LINES]
Displays the number of input signal display lines.
[COLOR FORMAT]
Displays the color format of the input signal.
[SAMPLING]
Displays the sampling information of the input signal.
[BIT DEPTH]
Displays the gradation of the input signal.
[SIGNAL LEVEL]
Displays the signal level of the input signal.
*1
The temperature status is indicated with text color (green/yellow/red) and bar scale. Use the projector within the range that the indication is
green.
*2 This is displayed only when the standard DC motor unit installed in the Zoom Lens (Model No.: ET-D75LE6, ET-D75LE8, ET-D75LE10,
ET-D75LE20, ET-D75LE30, ET-D75LE40, etc.) is replaced with the stepping motor unit using the Stepping Motor Kit (Model No.:
ET-D75MKS10), or when a projection lens with the stepping motor is attached.
*3 In the following cases, the recommended time to replace the filter is not set, and it is not displayed.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set to [NORMAL], [USER1], [USER2], or
[USER3], and the [PROJECTOR SETUP] menu
→
[FILTER SETTING]
→
[FILTER TYPE] is set to [LONG LIFE].
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set to [LONG LIFE1], [LONG LIFE2], or
[LONG LIFE3].
*4 If the runtime of the filter exceeds the recommended time to replace the filter, the runtime is displayed in red.
*5
[CONSOLIDATED RUNTIME] can be obtained with the following calculation formula. Values obtained by the calculation formula contain a
slight error.
Conversion formula for [CONSOLIDATED RUNTIME]
A
x 2.5 +
B
x 1.0 +
C
x 0.5 +
D
x 0.3 +
E
x 0.2
f
A
: Runtime of the light source with [OPERATING MODE] set to [HIGH]
f
B
: Runtime of the light source with [OPERATING MODE] set to [NORMAL], [USER1], [USER2], or [USER3]
f
C
: Runtime of the light source with [OPERATING MODE] set to [LONG LIFE1]
f
D
: Runtime of the light source with [OPERATING MODE] set to [LONG LIFE2]
f
E
: Runtime of the light source with [OPERATING MODE] set to [LONG LIFE3]
Note
f
The content of the status can be sent to the E-mail address (up to two addresses) set in “[E-mail set up] page” (
x
page 209) when the
<ENTER> button is pressed while displaying the pages 1/6 to 5/6 of the
[STATUS]
screen.
f
The detailed information of the input signal is displayed when the <ENTER> button is pressed while displaying the page 6/6 of the
[STATUS]
screen. Information for multiple input signals may be displayed depending on the projected image. Press
qw
to switch pages.
f
There are items that are displayed or not displayed in [SIGNAL INFORMATION] and [DETAILED INFORMATION] depending on the setting
or the input signal.
f
If any abnormality has occurred on the projector, press the <DEFAULT> button while the
[STATUS]
screen is displayed to display the detail
screen of the error information.
f
For details on the contents displayed in [SELF TEST], refer to “Self-diagnosis display” (
x
page 231).
[AC VOLTAGE MONITOR]
Enable or disable the AC voltage monitor function. The value of input supply voltage is displayed on the self-
diagnosis display at the side of the projector when enabled.
1) Press
as
to select [AC VOLTAGE MONITOR].
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Disables the AC voltage monitor function.
[ON]
Enables the AC voltage monitor function.
Note
f
When [ON] is set, the value of the input supply voltage is always displayed in the self-diagnosis display while the main power of the projector
is turned on.