Chapter 4
Settings — [PROJECTOR SETUP] menu
120 - ENGLISH
[REMOTE2 STATUS]
Displays the control status of the REMOTE2.
[AC VOLTAGE]
Displays the status of the AC voltage.
[COOLING CONDITION]
Displays the set cooling conditions. When [AUTO] is set, automatically recognized result is displayed.
[SIGNAL INFORMATION]
[MEMORY NO.]
Displays the memory number of the input signal.
[INPUT]
Displays the input terminal currently selected.
[SIGNAL NAME]
Displays the input signal name.
[SIGNAL FREQUENCY]
Displays the frequency of the input signal.
[SYNC.STATE]
Displays the synch polarity of the input signal.
[V.SYNC WIDTH]
Displays the vertical sync signal pulse width of the input signal.
[SCAN TYPE]
Displays the scan type of the input signal.
[TOTAL DOTS]
Displays the total dot count of the input signal.
[DISPLAY DOTS]
Displays the number of input signal display dots.
[TOTAL LINES]
Displays the total line count of the input signal.
[DISPLAY LINES]
Displays the number of input signal display lines.
[SAMPLING]
Displays the sampling information of the input signal.
[SIGNAL LEVEL]
Displays the signal level of the input signal.
[BIT DEPTH]
Displays the gradation of the input signal.
*1
The lamp runtime to be displayed is real time. The following conversion is required to calculate the rough estimate for lamp replacement.
Model No.
Formula for lamp replacement time (rough estimate)
PT-DZ13KU
PT-DS12KU
PT-DW11KU
(
A
x 56 +
B
x 40 +
C
x 35) ÷ 56
f
A
: Runtime when [LAMP POWER] is set to [HIGH]
f
B
: Runtime when [LAMP POWER] is set to [MIDDLE]
f
C
: Runtime when [LAMP POWER] is set to [ECO]
The formula when the optional Replacement lamp unit (for portrait mode) is used is:
A
+
B
+
C
PT-DZ10KU
(
A
x 40 +
B
x 35) ÷ 40
f
A
: Runtime when [LAMP POWER] is set to [NORMAL]
f
B
: Runtime when [LAMP POWER] is set to [ECO]
The formula when the optional Replacement lamp unit (for portrait mode) is used is:
A
+
B
Note
f
The content of status can be sent via E-mail by pressing the <ENTER> button while displaying the status.
f
Some items in [SIGNAL INFORMATION] may be displayed and others not displayed, depending on the signal being input.
f
If you attach a lamp unit used in a projector of a model different from the projector (PT-DZ13KU, PT-DS12KU, PT-DW11KU, PT-DZ10KU)
to the projector, or when the lamp unit used in the projector to a projector of a different model, the “lighting time” and “runtime” displayed in
[STATUS] may differ from the actual time.
[NO SIGNAL SHUT-OFF]
A function that automatically switches the power source of the projector to standby if there is no input signal for a certain period of time. The
time before switching to standby can be set.
1) Press
as
to select [NO SIGNAL SHUT-OFF].
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[DISABLE]
Disables the No signal shut-off function.
[10MIN.] - [90MIN.]
Allows you to set in ten minutes intervals.
[REMOTE2 MODE]
You can set the <REMOTE 2 IN> terminal.
1) Press
as
to select [REMOTE2 MODE].
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[DEFAULT]
The pin assignment of the <REMOTE 2 IN> terminal is used by the factory default setting of the
projector.
[USER]
Used to change the setting of the <REMOTE 2 IN> terminal.
[L6500 SERIES]
The setting of <REMOTE 2 IN> terminal is used for the L6500 series compatibility.