background image

Basic Instructions for the Use of This Product

For inspection and/or repair, consult the shop.

Use commercial power supply from a wall socket, which is close and easily accessible to 
this Ethernet Switch.

Unplug the power cord when installing or moving this Ethernet Switch.

Unplug the power cord when cleaning this Ethernet Switch.

Use this Ethernet Switch within the specifications. Deviation could lead to malfunction.

Do not touch the metal terminal of the RJ45 connector, the modular plug of connected 
twisted pair cable, or the metal terminal of the SFP extension slot. Do not place charged 
objects in the proximity of them. Static electricity could lead to equipment failure.

Do not put the modular plug of the connected twisted pair cable on objects that can 
carry static charge, such as carpet. Do not place it in the proximity. Static electricity could 
lead to equipment failure.

Do not put a strong shock, including dropping, to this Ethernet Switch. Deviation could 
lead to equipment failure.

Before connecting a console cable to the console port, discharge static electricity, for 
example by touching metal appliance (do not discharge by touching this Ethernet Switch).

Do not store and/or use this Ethernet Switch in the environment with the characteristics 
listed below. (Store and/or use this Ethernet Switch in the environment in accordance 
with the specification.)

-  High humidity. Possible spilled liquid (water).
-  Dusty. Possible static charge (such as carpet).
-  Under direct sunlight.
-  Possible condensation. High/low temperature exceeding the specifications 
environment.
-  Strong vibration and/or strong shock.

Please use this Ethernet Switch in place where ambient temperature is from 0 to 50°C.
Failure to meet the above conditions may result in fire, electric shock, breakdown, 

When connecting the stacks, be sure to use firmware versions that are identical for all 

of the devices.

Please note that operations are not guaranteed if the firmware versions are different.

Select the appropriate cables and lay them.
Communications might be affected by how the cables are laid, and environmental noise.

and/or malfunction. Please beware because such cases are out of guarantee.
Additionally, do not cover the bent hole of this Ethernet Switch.
Deviation could lead to high internal temperature, equipment failure and/or 
malfunction.

When stacking Ethernet Switches, leave a minimum of 20 mm space between them.

1. Please note that Panasonic shall not bear any liability whatsoever for any damages 

(this shall include, but is not limited to, lost earnings, lost opportunities, etc.)

 which were generated in relation to damages caused by operations and usage, 
or the inability to use this Ethernet Switch, whereby the customer does not follow 
this Installation Guide.

2. The contents described in this document may be changed without prior notice.
3. For any question, please contact the retailer where you purchased the product.

6

Summary of Contents for PN88162C-ID

Page 1: ...s are not covered by the warranty C0917 20122 ZEQUO 5410DL Model No Installation Guide Printed in Japan PN88162C TH PN88162C MY PN88162C ID PN88162C SG 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 105 0021 Panasonic Electric Works Networks Co Ltd Panasonic Electric Works Networks Co Ltd 2022 The instruction manuals CLI Version latest firmware and SDN application ZEQUO assist Plus can be download...

Page 2: ... Outline 1 1 Features 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 3 Installation and Configuration 3 1 Using 10GBASE T 3 2 Installing on level shelves 3 6 7 7 8 9 9 10 12 12 12 3 3 Mounting to rack 3 4 Configuration of IP address Basic Troubleshooting 12 13 15 ...

Page 3: ...ings or boards Do not use the Ethernet Switch in very dusty areas such as on floors underneath floors the backside of ceilings or boards Deviation could lead to fire electrical shock and or equipment failure It is recommended that the Ethernet Switch be operated in environments such as the inside of racks where it is difficult for dust to be generated Do not store or use the Ethernet Switch in pla...

Page 4: ...the optical fiber ports CAUTION Do not connect any other devices except for 100BASE TX 1000BASE T 10GBASE T devices to the twisted pair ports Deviation could lead to equipment failure Do not insert any other modules except for our optional SFP module PN54021K PN54023K and the SFP module PN59021 PN59023 to the SFP extension slots Do not insert any other modules except for our optional SFP module PN...

Page 5: ...bility It is recommended that this Ethernet Switch be replaced about five years after it has been installed This may vary depending upon conditions such as utilisation rates and usage environments but performance might decrease due to the age related degradation etc of components Be careful in regards to environmental restrictions whereby the Ethernet Switch can be used Please isolate the business...

Page 6: ...h the specification High humidity Possible spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Please use this Ethernet Switch in place where ambient temperature is from 0 to 50 C Failure to meet the above conditions may result in fire electric...

Page 7: ...ol RRP is supported allowing to make a redundant net work via ring topology If the stacking functions have been activated ports 15 and 16 will be stacking ports By using the SFP modules and the optical fiber cables or the SFP direct attach cables stacking connections are feasible for up to a maximum of two units whereas the ZEQUO 5410DL are used Equipped with two power ports power redundancy is fe...

Page 8: ...oping MLD Snooping QoS PQ WRR IEEE802 1X Port based MAC based Authentication MAC Authentication WEB Authentication Access control Storm control RRP IPv4 v6 routing IP forwarding Routing table size Max 7K IPv4 IPv6 7K VRRP RIP IP filtering DHCP relay DHCP client DHCP server DDM Twisted pair cable diagnostics ZEQUO assist Plus Console TELNET SSH SNMP MIB II RMON group 1 2 3 9 WEB Layer 3 Features Ma...

Page 9: ...162C ID PN88162C MY PN88162C SG 250 VAC 10 A AS NZS 3112 Australia New Zealand PN88162C NZ Power Cord Rating FUSE Rated Current Plug Type 1 4 Basic operation This Product does not have a power ON OFF switch Connect the supplied power cord to this Ethernet Switch and connect the other end into an electric outlet This Ethernet Switch operates at AC 100 240 V 50 60 Hz The Ethernet Switch is equipped ...

Page 10: ...When connecting via 100BASE TX 1000BASE T install the Ethernet Switch so that the twisted pair cable CAT5e or above lengths fall within 100 m or less SFP extension slot ports 5 16 An SFP or SFP module can be connected and be supported only the full duplex communication Stacking port ports 15 16 Up to four units can be stacked by connecting optical fiber cables or SFP direct attach cables Power por...

Page 11: ...ps or 10 Gbps Shutting off due to loop detection and shutoff functions storm controls BPDU guard Transmitting and receiving just the administration packets Shutting off due to loop detection and shutoff functions storm controls BPDU guard Transmitting and receiving just the administration packets Orange Light Orange Blink Off No devices is connected Green Light Link is established at 1000 Mbps or ...

Page 12: ...mental noise 1 Supported cable types 2 Cable laying environment 1 Apply the supplied rubber feet onto the bottom surface of the unit 2 Install in a level area Caution Do not stack and use Set up with a clearance of 20 mm or more Installation and Configuration 3 12 3 3 Mounting to rack Take out the supplied 2 mounting brackets for 19 inch rack and 8 screws for fixing the main unit and the mounting ...

Page 13: ...displayed Screen 2 4 Enter the IP address and subnet mask using the following command Screen 3 enable configure config interface vlan1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting Since the following screen is displayed enter Y and the settings will be saved Screen 4 config if exit config exit copy running config startup config 6 From terminals...

Page 14: ...settings and administration methods please see the PDF version of the Operating Instructions on Panasonic s website Detailed configuration and management methods using the CLI Configuration and management method from ZEQUO assist Plus 14 Installation and Configuration 3 ...

Page 15: ...pt to disable EEE conforming to IEEE802 3az LPI function at target port Are the communication speed and mode settings correct If the communication mode signal cannot be properly obtained the Ethernet Switch operates in half duplex mode Check the auto negotiation setting again Do not fix the speed duplex mode of the connected terminal to full duplex mode Is the usage rate of the network to which th...