136
Available commands are listed below.
U
Set the threshold for sending a trap.
Press "U." The command prompt changes to "Enter power usage threshold>." Enter the
threshold to send a trap.
M
Set the method to manage power supply.
Press "M." The command prompt changes to "Enter the power management method>."
Select and enter the management method. Enter "0" to shut down the port with low prior
-
ity and to supply power to the one newly connected. Enter "1" not to supply power to the
port connected next regardless of the value of priority.
Q
Return to the parent menu.
Note:
When the power supply amount is 169.5 W or less, if a IEEE802.3at compati
-
ble PoE power receiving device that consumes power of 15.4 W or more has
been newly connected and the power supply amount exceeds 185 W, power
supply to a port with a lower priority is always stopped regardless of the
Power Management Method settings. (If multiple ports have the same prior
-
ity, power supply to a port with a larger port number is stopped.)