170
UF-9000
APR 2006
Ver. 3.0
DP-180/190
068 NYSE Fax
Forward
(USA and Canada
Only)
1 = Off
2 = On
Selects whether the machine will forward the
incoming and outgoing faxes to a specified station.
Note:
Once this parameter is activated, Fax
Forwarding via Fax Parameter 054 is
automatically disabled, an Access Code of
"0000" is automatically assigned and Fax
Parameter 038 has a new setting added called
"NYSE".
069 NYSE Local Print
(USA and Canada
Only)
1 = Inc
2 = On (Always)
Selects the printing condition for the incoming faxes
after FAX Forwarding.
INC.
: Prints only if FAX Forwarding fails.
ON
: Always prints.
070 Line Error
128 lines
256 lines
512 lines
1024 line
2048 lines
Off
(will not disconnect line)
1. Selects the line disconnect condition during
reception. If the number of line errors exceed this
setting, the unit will disconnect the line.
Press “V” or “/\ “ to select the symbol rate.
2. Selects the transmit condition of RTP/PIP or
RTN/PIN.
(Available if No.73 Error Detect is set to "LINES")
(See Note 1)
071 Total Error
1 = 5%
2 = 10%
3 = 15%
4 = 20%
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
072 Continuous Error 1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
Selects the continuous total error criteria of Off/3/6
or 12 lines in Standard mode. If continuous total
error exceeds this setting, the unit will transmit
RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
073 Error Detect
1 = Lines
2 = Rate
Selects the error detect condition Lines/Rate.
074 RTN Receive
1 = Disconnect
2 = Continue
Selects whether to disconnect the phone line or
continue when "RTN" is received.
075 Coding
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
4 = JBIG
Selects the coding scheme.
076 Batch TX
(USA and Canada
Only)
1 = Off
2 = On
Selects whether the batch transmission is available.
077 RX JAM Length
1 = Off (unlimited)
2 = 2 m
Selects the maximum length of a received
document that can be printed.
078~
079
Not Used
080 Doc Top Feed
-99
~
+99
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
081 Doc End Feed
-90
~
+127
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for Panafax UF-9000
Page 50: ...50 UF 9000 APR 2006 Ver 3 0 DP 180 190 21 Remove the LCD Module 127...
Page 74: ...74 UF 9000 APR 2006 Ver 3 0 DP 180 190 3 3 Preventive Maintenance Points...
Page 126: ...126 UF 9000 APR 2006 Ver 3 0 DP 180 190 Sensor and Switch Location...
Page 341: ...341 UF 9000 APR 2006 Ver 3 0 DP 180 190 memo...
Page 343: ...343 APR 2006 Ver 3 0 UF 9000 DP 180 190 memo...
Page 359: ...Published in Japan...
Page 375: ...Published in Japan...