5
If your oven is to be vented into the kitchen, the standard charcoal
fi
lter is already installed in your oven, ready
for recirculating mode.
When you replace the charcoal
fi
lter, refer to the instructions in the Operating Instructions (Maintenance/Care
and Cleaning of Your Microwave Oven).
Changing the exhaust direction to the recirculating mode
(1) Remove two blower cover plate mounting screws and two blower unit mounting screws (top and rear).
(Fig.
1-2-1)
(2) Remove the blower plate from the product. (Fig. 1-2-1)
Blower Unit
Mounting Screws
Blower Plate
Mounting Screws
Blower Unit
Back Plate
Blower Plate
Blower Unit
Mounting Screws
Fig. 1-2-1
(3) Carefully lift the blower unit out of the product, and rotate blower unit 90 degrees so the exhaust ports are
facing toward the front of the product. (Fig. 1-2-2)
Blower Unit
Fig. 1-2-2
(4) Replace blower unit back into product. Be careful not to pinch the lead wires between blower unit and oven
top. Make sure the fan blades are visible through the front exhaust openings. (Fig. 1-2-3)
Flat surface of blower unit
(No exhaust shown on top)
Fig. 1-2-3
IP2386_38Q01CP_Eng_04_080105.indd 5
IP2386_38Q01CP_Eng_04_080105.indd 5
2009-1-6 Michael 9:16:48
2009-1-6 Michael 9:16:48