After replacing the Cylinder Unit, press COUNTER RESET button
on remote in this mode. Only Total lapsed time with Cylinder
rotation (hour) will be cleared to 0.
2. To release from Usage Screen Mode, press any operation button
on VCR in this mode. VCR will return to normal operation mode.
4.1.3. EEPROM IC (IC6005), MAIN C.B.A. REPLACEMENT NOTE
After replacing EEPROM IC (IC6005) or Main C.B.A., be sure to perform the "
PG SHIFTER
ADJUSTMENT
" in ELECTRICAL ADJUSTMENT procedures.
4.1.4. SERVICE POSITION
4.1.4.1. Service Position
CAUTION:
HOT CIRCUIT (Primary circuit) exists on the Main C.B.A.
Use extreme care to prevent accidental shock when servicing.
4.1.4.1.1. Service Position (1)
Fig. 2-1
4.1.4.1.2. Service Position (2)
Fig. 2-2
Summary of Contents for OmniVision PV-QV200
Page 24: ...5 2 2 Inner Parts Location Fig J1 1 ...
Page 25: ...5 2 3 EJECT Position Confirmation Fig J1 2 ...
Page 26: ...5 2 4 Grounding Plate Unit Full Erase Head and Cylinder Unit Fig J2 1 ...
Page 40: ...5 3 CASSETTE UP ASS Y SECTION 5 3 1 Top Plate Wiper Arm Unit and Holder Unit Fig K1 1 ...
Page 86: ...10 2 MECHANISM BOTTOM SECTION ...
Page 87: ...10 3 CASSETTE UP COMPARTMENT SECTION ...
Page 88: ...10 4 CHASSIS FRAME AND CASING PARTS SECTION ...
Page 89: ...10 5 PACKING PARTS AND ACCESSORIES SECTION ...
Page 117: ...R3036 ERJ6GEYJ122V MGF CHIP 1 10W 1 2K ...
Page 123: ...ECKATS101MB CERAMIC 20 250V 100P ...