11.1.6. Damper motor:
Being used in electronic no-frost models.
It controls the cold air coming from the freezer via air duct.
Note:
When to replace damper motor; replace Freezer multiflow
cover assy (including damper motor). Because freezer multi-
flow cover insulation will be broken when to disassemble
Freezer cover assy. To take out damper motor.
11.1.7. Sensor
Sensors used at electronic models shows different resistance
values for various ambiance temperatures.
These resistance values are indicated below:
11.1.8. Thermal Fuse Control
Thermal fuse must be checked and if it is open circuit; needs to
be replaced.
Notice:
Defrost sensor and thermal fuse must be measured with ohm-
meter.
11.1.9. Defrost heater Durability Control
Defrost heater must be measured with ohm-meter. If there is
open circuit they need to be replaced.