18
5.3.4.
Inspect inlet valve
5.3.4.1.
Check electric part
1. Open the protecting box and take out the PCB;
2. With the door closed, unplug the CON3 and ACN wires, then use the multi-meter
Ω
shelf to measure resistance between the
blue wire (EV1) and the blue wire (ACN), the normal resistance is about 3.4K
Ω
to 4.4K
Ω
.
3. If the measured resistance is not correct, it means the valve coil is broken or the connector is loose. In this case, we should
check the connection first. If the problem hasn’t been solved by re-connection, we should replace the valve.
4. If the resistance is OK, we need to inspect the valve body.
5.3.4.2.
Check machine part
1. If the electric part is OK, we need to check the machine part.
2. Check the valve filter. if the valve filter is blocked, we need clear the residues.
3. If the valve filter is clear and the valve can’t inlet water, check whether valve can act or not. If it isn’t, we need replace the
valve.
4. If the water is continue entering, we need replace the valve.
Summary of Contents for NP-6F2MUQNZ-NZ
Page 11: ...11 4 Block Diagram 4 1 Water Circuit ...
Page 13: ...13 5 Troubleshooting 5 1 Location ...
Page 33: ...33 5 13 Inspection 5 13 1 E1 tree ...
Page 34: ...34 5 13 2 E3 tree ...
Page 35: ...35 5 13 3 E4 tree ...
Page 37: ...37 5 14 Troubleshooting ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 41: ...41 ...
Page 44: ...44 7 Exploded View 112 111 107 109 106 108 101 115 104 105 102 103 110 104 113 114 ...
Page 45: ...45 201 202 203 204 207 210 203 209 208 217 218 220 221 219 214 212 213 211 216 216 326 326 ...
Page 48: ...48 501 505 510 511 512 513 ...
Page 49: ...49 601 604 605 606 607 609 610 611 612 614 618 624 625 628 629 630 631 632 ...
Page 50: ...50 701 705 709 711 ...
Page 51: ...51 P1 P2 P3 P5 P4 ...