![Panasonic NP-6F2MUQNZ-NZ Service Manual Download Page 31](http://html.mh-extra.com/html/panasonic/np-6f2muqnz-nz/np-6f2muqnz-nz_service-manual_265103031.webp)
31
5.12. Error code
5.12.1. How to know which error code has occurred
To know which error code has occurred, refer to the previous table named Test Program Operation.
If the error 1 has happened, the buzzer would alarm for 30 seconds and “E1” would be shown on display. Other error alarms would
be shown in the same manner.
The corresponding relation between indicator combination and error code shown in above figure.
5.12.2. Attention
Priority level of E4 is the highest. E4 operation is valid after other error operations have done. When E4 operation has done, all the
others are invalid.
In test program, E1, E3, E4, E6, E7 and E8 are valid.
Note: E8 is valid for models equipped with diverter valve (alternative washing function).
Summary of Contents for NP-6F2MUQNZ-NZ
Page 11: ...11 4 Block Diagram 4 1 Water Circuit ...
Page 13: ...13 5 Troubleshooting 5 1 Location ...
Page 33: ...33 5 13 Inspection 5 13 1 E1 tree ...
Page 34: ...34 5 13 2 E3 tree ...
Page 35: ...35 5 13 3 E4 tree ...
Page 37: ...37 5 14 Troubleshooting ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 41: ...41 ...
Page 44: ...44 7 Exploded View 112 111 107 109 106 108 101 115 104 105 102 103 110 104 113 114 ...
Page 45: ...45 201 202 203 204 207 210 203 209 208 217 218 220 221 219 214 212 213 211 216 216 326 326 ...
Page 48: ...48 501 505 510 511 512 513 ...
Page 49: ...49 601 604 605 606 607 609 610 611 612 614 618 624 625 628 629 630 631 632 ...
Page 50: ...50 701 705 709 711 ...
Page 51: ...51 P1 P2 P3 P5 P4 ...