5.8.2.
Inspect NTC
1. Open the protecting box and take out PCB;
2. With the door closed,unplug the RE connector (shown in below picture), then use the multi-meter
Ω
shelf to test resistance
between two blue wires (RE and GND), the normal resistance is shown in below table.
3. If the resistance is not correct, it means NTC circuit has a problem. In this case, we should check the connection first. If the
problem hasn’t been solved by re-connection, we would replace the NTC.
NTC resistance table
NTC
15°C
17.48K
Ω
20°C
12.12K
Ω
25°C
10K
Ω
30°C
8.299K
Ω
40°C
5.807K
Ω
50°C
4.144K
Ω
60°C
3.011K
Ω
70°C
2.224K
Ω
80°C
1.667K
Ω
85°C
1.451K
Ω
Summary of Contents for NP-6F2MUQNZ-NZ
Page 11: ...11 4 Block Diagram 4 1 Water Circuit ...
Page 13: ...13 5 Troubleshooting 5 1 Location ...
Page 33: ...33 5 13 Inspection 5 13 1 E1 tree ...
Page 34: ...34 5 13 2 E3 tree ...
Page 35: ...35 5 13 3 E4 tree ...
Page 37: ...37 5 14 Troubleshooting ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 41: ...41 ...
Page 44: ...44 7 Exploded View 112 111 107 109 106 108 101 115 104 105 102 103 110 104 113 114 ...
Page 45: ...45 201 202 203 204 207 210 203 209 208 217 218 220 221 219 214 212 213 211 216 216 326 326 ...
Page 48: ...48 501 505 510 511 512 513 ...
Page 49: ...49 601 604 605 606 607 609 610 611 612 614 618 624 625 628 629 630 631 632 ...
Page 50: ...50 701 705 709 711 ...
Page 51: ...51 P1 P2 P3 P5 P4 ...