5. FEED VALVE replacement.
a. Take DETERGENT CASE B out.
b. Remove LEAD WIRE CONNECTOR.
c. Remove 4 screws mounting the DETERGENT
CASE AU and FEED VALVE SUPPORT .
d. Pull DETERGENT CASE AU out.
e. Remove 2 screws mounting the FEED VALVE
(for clod water).
f. Move the spring by pliers than pull the FEED
VALVE (for hot water) out of the FEED HOSE.
6. The NOISE PCB replacement.
a. Remove 1 screws mounting the PCB.
b. Pull the PCB out.
c. Remove the PCB Cover, then remove
the lead wire connector.
Feed
Lead Wire
PULL
NOISE PCB
PCB Cover
PULL OUT
PULL OUT
-12-