36
Error Display
Unable to drain
What to do
Check the drain hose for any of following problems:
- It is blocked with debris.
- Hose tip is immersed in water.
- It extends further than 3 m.
- Water in the pipe is frozen.
Clean the drain filter if blocked. (P.31)
After correcting the problem, open the door then close it, then press
the start button to restart the machine.
Door is open
What to do
Make sure that door is closed properly.
Close the door securely and press the start button.
Unable to supply
water
What to do
Check for any of following problems:
- Supply tap is closed.
- Water pipe or hose is frozen.
- Water supply has been disrupted.
- Water supply filter is blocked. (P.29)
After correcting the problem, open the door then close it, then press
the start button to restart the machine.
If the red mark appears in the hose with a water supply valve, the
water supply has stopped.
Replace with a new hose.
Hose with water supply valve (No. AXW-598865)
An error starting with “H” is displayed.
What to do
Press the Off button. If the display stays on, or if the error message
appears again when you press the Start button, unplug the
machine and contact your local Customer Service Centre.
37
Tr
ou
bl
es
ho
ot
in
g
In
st
al
la
tio
n
Se
rv
ic
e
pe
rs
on
o
nl
y
Installation / Others
Choosing the Right Location
●
Make sure to ask a service person for installation. Do not install by yourself.
●
If the installation, test run and inspection of the washing machine are not
carried out following this installation method, Panasonic will not be liable for
any accident or damage caused.
■
Locations the appliance is not to be installed
- In a damp place or where the
appliance may be exposed to rain,
etc. (As this could cause electric
shock or fire)
- Locations that are uneven, or
unstable (As this could cause
vibration and noise)
- In direct sunlight (As this could cause
a malfunction or deformation)
■
Appliance dimensions
■
Set-in installation
- Install the appliance with easy
access to the mains plug and socket.
- Install the appliance where there is
enough space around it.
CAUTION
Do not install where temperatures
may reach freezing.
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(b)
(a)
(a): 582 mm
(b): 596 mm
(c): 183 mm
(d): 840 mm
(e): 34 mm
(f): 499 mm
(g): 593 mm
(h): 635 mm
(i): 1103 mm
(a)
(b)
(c)
(d)
(e)
(a): 3 mm or more above
(b): 3 mm or more behind
(c): 2 mm or more on the left side
(d): 2 mm or more on the right side
(e): 60 cm or more