35
11.3. Resistance
Heating element (Resistance) is a component which is des-
ingned to regulate temperature of water inside the drum. It has
three connections: Phase, notral and ground connections.
11.3.1. Technical Features
11.3.2. Checking of Component
Check the resistance value on the component with multimeter
as shown in below pictures.
Checking the component
11.3.3. Component Controlling By Con-
nection Measurement
You can determine the ohm value by measuring from the grey
cable at 13th and brown cable at 4th position in the small
socket (refer to 13 Wiring Connection Diagram) as shown in
belows figures.
Resistance value should be between 23 - 27 Ohm.
Kind of heating
Tubular heating element with NTC - sensor
Nominal voltage
230 V
Nominal power
2000 W (±5 %)
Resistance
24,8 ±5%
Ω
(for NA-127VB3 and NA-147VB3)
25,2 ±5%
Ω
(for NA-128VB3 and NA-148VB3)
Thermal fuse
2 - sided
Summary of Contents for NA-127VB3
Page 3: ...3 1 Safety Precautions ...
Page 6: ...6 4 Location of Controls and Components ...
Page 13: ...13 ...
Page 43: ...43 12 Dimensions ...
Page 44: ...44 13 Wiring Connection Diagram 13 1 Wiring Diagram NA 127VB3 and NA 147VB3 ...
Page 45: ...45 ...
Page 46: ...46 13 2 Wiring Diagram NA 128VB3 and NA 148VB3 ...
Page 47: ...47 ...
Page 51: ...51 14 3 Washing Group Parts 14 3 1 Exploded View Washing Group Parts ...
Page 54: ...54 14 5 Detergent Drawer Group Parts 14 5 1 Exploded View Detergent Drawer Group Parts ...
Page 57: ...57 14 7 Body Group Parts 14 7 1 Exploded View Body Group Parts ...