95
-
-
94
-
Conformance to EC directive and UL standard
• DV0P4190
• DV0P1450
Circuit diagram
1
ø4.2±0.2
41±1
UL-1015 AWG16
28±1
5.5
±1
11
±1
28.5±1
4.5
±0.5
200
+30 −0
2 3
[Unit: mm]
Circuit diagram
ø4.2±0.2
41±1
UL-1015 AWG16
28±1
5.5
±1
11
±1
28.5±1
4.5
±0.5
200
+30 −0
1 2
[Unit: mm]
①
② ③
①
②
Recommended circuit breaker (MCCB)
Made by Sensata Technologies Japan Limited:
Type IELH-1-11-63-5A-M (single phase) Type IELH-1-111-63-5A-M (3-phase)
(Rated current 5A, cutoff characteristics DELAY63)
• Recommended cutoff characteristics: DELAY61-63
Surge absorber
Noise filter for control signals
39±1
34±1
30±1
13±1
mass: 62.8g
[Unit: mm]
• DV0P1460
Specifications
• Brushless motor specifications
Item
Specifications
Flange size
80 mm sq.
90 mm sq.
Motor model No.
MBMU5AZAB
MBMU9A1AB MBMU9A2AB MBMU1E1AB MBMU1E2AB
Motor rated output (W)
50
90
130
Voltage
for 100 V/200 V
for 100 V
for 200 V
for 100 V
for 200 V
Rated torque (N
・
m)
0.16
0.29
0.41
Starting torque
*1
(N
・
m)
0.24
0.43
0.62
Rated input current
(A(rms))
0.53
0.53
1.00
0.50
1.30
0.72
Moment of inertia of
rotor
(
×10
−4
kg
・
m
2
)
0.12
0.27
0.36
Rating
Continuous
Rated rotation speed
*2
(
r/min
)
3000
maximum rotation
speed
(
r/min
)
4000
Speed control range
(r/min)
30 to 4000
Axial runout
0.05 mm or less at the position of 3 mm from the shaft end
Bearing
Ball bearing
Insulation
resistance
Measure the insulation resistance with 500 V Megger. It must be above 20 MΩ
Measuring position: Between power input line (L1, L2,L3) and grounding wire
Isolation voltage
1500 VAC, 1 minute, 10 mA or less (between power and grounding wire)
Ambient temperature
−10 ℃ to +40 ℃ (free from freezing)
* Ambient temperature is measured at a distance of 5 cm from the motor.
Ambient humidity
20 to 85% RH (free from condensation)
Altitude
Lower than 1000m
Vibration
4.9 m/s
2
or less (10 to 60 Hz) X, Y, Z
Impact
Lower than 98m/s
2
Motor insulation class
130(B) (UL certified 105 (A))
Storage temperature
–20˚C to 60˚C ( free from condensation)
*Extreme temperatures are permissible only for short period such as during transportation.
Storage humidity
85%RH or below (free from condensation)
Protection structure
IP65
*3
Number of poles
8
Motor mass (kg)
0.7
1.0
1.2
*1 Representative value
*2 Motor shaft speed: to be multiplied by the reduction ratio when the gear head is used.
*3 Excluding the shaft pass-through section and cable end connector.
* Should conform to the test conditions specified in EN standard (EN60529 and EN60034-5).
Not suitable for application where watertightness is required over a prolonged period, even if
frequently washed.
• Standard characteristics measurement conditions are temperature of 25 °C and relative humidity of
65%, and may be extended to 5 to 35 °C and 45 to 85% RH.