3.1. Fan Motor
3.1.1. Removal
1. Remove dust cover.
2. Remove four (4) screws from motor case.
3. Remove motor case.
4. Remove motor unit.
5. Remove the noise suppressor, front and rear motor
supports, and motor cap to expose electrical connections.
6. Disconnect lead wires from motor.
7. Discard old motor.
NOTE: For general servicing, it is necessary to eliminate
pinching of any wire during reassembly. After servicing
any electrical component or electrical enclosure, the
vacuum cleaner should be reassembled and checked for
dielectric breakdown or current leakage.
3.1.2. Installation
1. Connect lead wires to the appropriate terminals on the
motor (see WIRING DIAGRAM).
2. Place front and rear motor supports and motor cap on new
motor.
3. Wrap noise suppressor around the motor.
4. Reinstall motor into the dust compartment with the tabs on
the motor support rear aligned parallel to the front edge of
the dust compartment.
5. Rewire per the Pictorial Wiring Diagram and Wiring
Management Drawing.
6. Reinstall motor case and and secure in place with four (4)
screws.
7. Reinstall dust cover.
3 SERVICE PROCEDURES - BODY
11