- 13 -
H) BLOCKAGES
Suction Inlet
Secondary
Filter Screen
Hose Inlet
A
B
B
A
Hose Coupling
The hose located on the vacuum cleaner carries the dirt
from the nozzle up to the dust bin. If the hose should
become clogged:
Unplug the cleaner from mains outlet.
Remove hose coupling and check hose coupling and hose
inlet for clogs according to the following procedure.
To remove hose coupling:
1.Depress and rotate tab A as shown.
2.Once tab A is clear of the vacuum cleaner inlet, depress
and rotate tab B as shown.
To re-install hose coupling: Reverse steps above.
Check suction inlet and secondary filter screen for clogs.
Disconnect wand from connector pipe and nozzle hose,
check the wand and hose. Plug in vacuum cleaner and turn
on.
Disconnect wand and stretch hose in and out to remove
clog. If clogs still exist, turn the cleaner over and inspect agi-
tator area for clogs, see page 11 for details.