7.3.2. Flowchart of Adjusument
* In case that the process of Disassembly->Assembly->Inspection repeated for 3 times,
we suppose that the lens was NG and it needs to be replaced by new Lens.
Visual Checking
Removal glue around 3 Adjustment Pins/Screws
TELE end
Simple Resolution
Real Time
Adjustment
- Check the brightness
and settings of camera
body and test chart
- Begin again after
disassembly/assembly
- Begin again after
disassembly/assembly
Failure, it needs to be
replaced by new lens
NG
Disassembling Decoring Unit and Filter Ring
Setting to Simple Resolution Real Time Adjustment
( "7.4.1.2" , in detail )
WIDE end
Simple Resolution
Real Time
Adjustment
TELE end
Simple Resolution
Real Time
Adjustment
Glue 1st Lens Frame Adjustment Pins/Screws
Assemblig Decoring Unit and Filter Ring
OK
OK
OK
OK
NG
NG
NG
Finish
22