7.4.2-2. Pre-setting
Prior to the 1st Lens Frame Adjustment, setup service equipment as follows:
1. Attach the lens adaptor (SUKZ000031) to the lens projector (SUKZ000030).
Note:
- Make sure that Chart inside and out / ups and downs is right position.
(At a time of shipment, the Projector Chart (SUKZ000032) is aligned and fixed to the Lens adaptor (SUKZ000031) ,
and are supplied as a unit, therefore, do not disassemble them.)
- Confirm that Chart base point line matches with Projector mount base point line and then tighten screw.
2. Attach the Lens Control Adaptor (SUKZ000033) to the General-purpose camera, then connect the flexible cable
from the lens control adaptor to the lens adaptor.
3. Attach the repair Lens to Projector mount.
Note:
- Before mounting the Repair Lens, Decring Unit / Filter Ring are uninstalled.
- Remove Lock Tight by alcohol on the Adjustment Pin.
7.4.2-3. Projector / General-Purpose Camera / Repair Lens setting
1. Turn on the lens projector so that the projector chart image is projected on wall.
2. Turn on the general purpose camera body to activate OIS of the repair lens.
(The OIS lens moves to center of optical axis)
3. Keep
3 m
distance between Lens Projector and wall which is chart image is projected.
4. Place Hand mirror in the center of projected chart image.
Using the Hand mirror light reflection, align the projector positioning so that the repair lens and chart image on the
wall becomes orthogonal condition.
After position alignment has been completed, then remove the hand mirror.
(Including tilt )
Lens Projector
(SUKZ000030)
Lens Adaptor
(SUKZ000031)
Repair Lens
Lens Control Adaptor
(SUKZ000033)
General-Purpose Camera Body
(Any LUMIX G series camera body)
Projector Chart
(SUKZ000032)
Projected chart image on the wall
Beaming
Refracting
Hand mirror
(Position alignment purposes.)
Lens Projector
Repair Lens
Height
Positioning
90 degree
29