40
9.4.7.
MeShut Calibration
1. Setting the DSC.
1-1) Set the battery to the camera.
1-2) Insert the SD memory card containing the “Enable
Test.txt” into the camera.
1-3) Turn off the power.
1-4) Continue pushing ”
W KEY” +“
MENU/SET”
+”
Playback” at the same time during several seconds.
* Please press "
Playback " last.
It starts in the state of “Engineer Mode” automatically.
1-5) Press “Playback” to enter selection menu.
1-6) To Select the Light box mode, carry out the following
operations.
a. Select the item “WB/AGC” by Cursor key, and press
“Playback.
b. Select the item “Light Src”, and set the value as
“00002” by Cursor key, then press “Playback”.
1-7) Set the DSC to the front of Light Box closely.
2. Execute Calibration.
2-1) Choose “MeShut80” by Cursor key, and press “Play-
back”.
2-2) Change the flag status of “Disable” from 00001 to
00000 by Cursor key (Left / Right), and then press “Menu/
Set”.
2-3) Press “Menu/Set”, and select “OK”, and press
“Menu/Set” again to start checking.
2-4) When calibration finishes, the screen will show the
result “OK” or “NG”.
(If the adjustment result of Meshut80 is OK, the result of
M26 will also be OK automatically.)
2-5) Press “Playback” to return to calibration menu.