Panasonic LS-400 Series Manual Download Page 8

8

Digital Laser Sensor 

LS-400

 

SERIES

Designation

Model No.

Description

Sensor head 

mounting 

bracket

MS-CX-1

Foot angled mounting bracket

MS-CX-2

Foot biangled mounting bracket

Flat mounting possible to avoid obstructions caused by the height of the sensor.

MS-CX-3

Back angled mounting bracket

MS-CX-4

Protective mounting bracket

Protects sensors preventing beam axis displacement due to shocks.

Sensor mounting 

bracket for beam 

axis alignment

MS-CX-11

Mounting bracket that makes fine beam axis alignment possible 

after setting the sensor head.

Adjustment angle: up and down, right and left: 4 degrees

Mounting directions: two directions, vertical and horizontal

Universal sensor 

mounting stand

MS-AJ1

Horizontal mounting type

Basic assembly

MS-AJ2

Vertical mounting type

MS-AJ1-A

Horizontal mounting type

Lateral arm assembly

MS-AJ2-A

Vertical mounting type

Amplifier mounting bracket

MS-DIN-2

Mounting bracket for amplifier

Reflector mounting bracket

MS-RF23

Mounting bracket for 

RF-230

Amplifier 

protection seal

FX-MB1

10 sets of 2 communication window seals and 1 connector seal

Communication window seal:  It prevents malfunction due to transmission signal from another 

amplifier, as well as, prevents effect on another amplifier.

Connector seal:  It prevents contact of any metal, etc., with the pins 

of the quick-connection cable.

Reflector

RF-310

For coaxial retroreflective type

Compact reflector

Sensing range (U-LG mode)

• 

LS-H91

(

F

):  0.1 to 7 m 

0.328 to 22.966 ft

• 

LS-H91

(

F

)

-A

:  0.1 to 5 m

 

0.328 to 16.404 ft

Reflective tape

RF-33

For coaxial retroreflective type

Size: 25.2 × 27.8 × t 0.4 mm

0.992 × 1.094 × t 0.016 in

RF-31

For coaxial retroreflective type

Size: 9.2 × 9.2 × t 0.4 mm

0.362 × 0.362 × t 0.016 in

Bank  

selection unit

FX-CH

NPN input type

Setting for up to 16 laser sensors can be 

changed at once by means of external signals.

FX-CH-P

PNP input type

Sensor head mounting bracket

• MS-CX-1

• MS-CX-2

Two M3 (length 12 mm  

0.472 in

) screws with  

washers are attached. 

Two M3 (length 12 mm 

0.472 in

) screws with 

washers are attached.

Universal sensor mounting stand

45° 

45° 

Elevation 

angle: ±45° 

Swivel:

  360° rotation

Mounting hole

for M6 screw

Height

adjustment:

150 mm

5.906 in

approx.

• MS-AJ1

• MS-AJ1-A

45° 

45° 

Angle 

adjustment: 

±45° 

Swivel: 

  360° 

     rotation 

Mounting hole 

for M6 screw 

360° 

With the lateral arm, 

the sensor can 

sense from above 

a production line. 

Forward / back 

adjustment  

130 mm  

5.118 in

  

approx. 

Height

adjustment:

150 mm

5.906 in

approx.

• MS-AJ2

45° 

45° 

Elevation 

angle: 

±45° 

Mounting hole

for M6 screw

Height

adjustment:

150 mm

5.906 in

approx.

Swivel:

  360° rotation

• MS-AJ2-A

360° 

45° 

45° 

Angle 

adjustment: 

±45° 

With the lateral arm, 

the sensor can 

sense from above a 

production line. 

Swivel: 

360° rotation 

Mounting hole 

for M6 screw 

Forward / back 

adjustment  

130 mm 

5.118 in

  

approx. 

Height

adjustment:

150 mm

5.906 in

approx.

Reflector

• RF-310

24 mm

0.945 in

12 mm

0.472 in

4 mm

0.157 in

Reflective tape

• RF-33

27.8 mm

1.094 in

0.4 mm

0.016 in

25.2 mm

0.992 in

• RF-31

9.2 mm

0.362 in

0.4 mm

0.016 in

9.2 mm

0.362 in

OPTIONS

• MS-CX-3

• MS-CX-4

Two M3 (length 12 mm  

0.472 in

) screws with  

washers are attached. 

Two M3 (length 12 mm  

0.472 in

) screws with  

washers are attached. 

Sensor mounting bracket 

for beam axis alignment

Amplifier mounting bracket

• MS-DIN-2

Reflector mounting bracket

• MS-RF23

Two M4 (length 10 mm 

0.394 in

)

screws with washers are attached.

Amplifier protection seal

• FX-MB1

Communication

window seal

Connector seal

• MS-CX-11

Two M3 (length 14 mm 

0.551 in

) screws with 

washers are attached.

Bank selection unit

• FX-CH

(

-P

)

Summary of Contents for LS-400 Series

Page 1: ...2022 6 Amplifier separated Digital Laser Sensor LS 400SERIES The contents of this catalog are as of October 2017 For the latest information please visit our company website...

Page 2: ...e type LS H21 Easy to use sealing type reflective tape available Easy to use sealing type reflective tape available 500 mm 19 685 in A spot diameter of approx 1 mm 0 039 in at a 1 000 mm 39 370 in sen...

Page 3: ...ighly reliable built in multiple turn type knob allows you to adjust the spot shape easily Easy and accurate adjustments A spot size adjuster is built into the back of the sensor head allowing the use...

Page 4: ...iers check the instruction manual for the amplifiers when connecting them Wiring and space saving The quick connection cables enable reductions in wiring connector type The connections and man hours f...

Page 5: ...load emission halt function and D CODE values can be stored in CUSTOM mode The settings are changed easily Emission halt function If you do not want to place a laser spot in the visual range of the im...

Page 6: ...11 in LS H22F Note 2 3 FDA IEC JIS NOTE Mounting bracket is not supplied with the sensor head Please select from the range of optional sensor head mounting brackets Notes 1 Obtained Korea s S mark cer...

Page 7: ...h 2 m 6 562 ft CN 74 C5 Length 5 m 16 404 ft Sub cable 2 core CN 72 C1 Length 1 m 3 281 ft 0 2 mm2 2 core cabtyre cable with connector on one end Cable outer diameter 3 3 mm 0 130 in CN 72 C2 Length 2...

Page 8: ...ve type Size 9 2 9 2 t 0 4 mm 0 362 0 362 t 0 016 in Bank selection unit FX CH NPN input type Setting for up to 16 laser sensors can be changed at once by means of external signals FX CH P PNP input t...

Page 9: ...F Ambient humidity 35 to 85 RH Storage 35 to 85 RH Ambient illuminance Incandescent light 3 000 x or less at the light receiving face Voltage withstandability 1 000 V AC for one min between all suppl...

Page 10: ...adjustment function Incorporated Timer function Incorporated with variable ON delay OFF delay One shot timer switchable either effective or ineffective Timer period 1 to 9 999 ms approx 0 5 ms approx...

Page 11: ...n sub cable does not have brown lead wire and blue lead wire The power is supplied from the connector of the main cable 2 The quick connection cable does not have a pink lead wire Terminal layout of c...

Page 12: ...nce However if the adjuster is turned too far it may be damaged Safe use of laser products For the purpose of preventing users from suffering Never use this product as a sensing device for personnel p...

Page 13: ...0 5 sec approx after the power supply is switched on Because the sensitivity is higher in U LG mode than in other modes it can be more easily affected by extraneous noise Check the operating environm...

Page 14: ...00 78 740 Amplifier LS 401 LS 401P LS 403 Amplifier LS 401 C2 LS 401P C2 11 0 433 10 0 394 75 2 953 27 8 1 094 3 0 118 30 1 181 24 0 945 Communication window Suitable for 35 mm 1 378 in width DIN rail...

Page 15: ...992 27 8 1 094 RF 31 9 2 0 362 9 2 0 362 2 3 2 0 126 holes 2 0 079 t 1 t 0 039 0 4 0 016 7 5 0 295 4 2 0 165 2 0 079 1 8 0 071 3 2 0 126 5 2 0 205 8 5 0 335 5 2 0 205 3 2 0 126 5 0 197 21 6 0 850 16 0...

Page 16: ...or mounting bracket for RF 230 Optional Assembly dimensions 40 1 575 4 5 0 177 28 3 1 114 19 3 0 760 8 3 0 327 50 3 1 980 61 3 2 413 7 0 276 49 3 1 941 5 0 197 40 1 575 t 2 t 0 079 10 0 394 10 0 394 3...

Page 17: ...sal sensor mounting stand Optional 25 5 1 004 10 0 394 2 6 6 0 260 mounting holes 45 1 772 32 1 260 Base PA 8 0 315 18 0 709 20 0 787 28 1 102 28 45 1 120 12 0 472 16 5 0 650 147 5 787 Note 1 44 5 1 7...

Page 18: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent...