background image

Min. 

Min. 

0 cm

0 cm

Min. 

Min. 

0 cm

0 cm

Min. 100 cm 

Min. 100 cm 

clearance 

clearance 

to the ceiling

to the ceiling

Min. 

Min. 

5 cm

5 cm

Min. 

Min. 

5 cm

5 cm

Min. 100 cm 

Min. 100 cm 

clearance 

clearance 

to the ceiling

to the ceiling

710

+3

0

R3

+

1

368

+3

0

Cabinet front

Partition 

board

Countertop

More 

than 100

Holes

(approx. 

Φ

 100×8)

Min. 70 cm 

Min. 70 cm 

clearance to 

clearance to 

the ceiling

the ceiling

Min. 70 cm 

Min. 70 cm 

clearance to 

clearance to 

the ceiling

the ceiling

More than 470

Intake

More than 6*

(12 to 30)

368

+3

0

 (Depth of mounting hole)

Exhaust vent

Flow from intake to exhaust

Min. 

Min. 

1 cm

1 cm*

Min. 

Min. 

0 cm

0 cm

Min. 

Min. 

5 cm

5 cm

Min. 

Min. 

5 cm

5 cm

4

5

 

• If the front countertop has a bulge

Installation Location

Related Dimensions 

(Built-in)

 

Dimensions of countertop cutout

Cut according to the template included 

with the appliance.

 

• Including heat-insulating board made of metal, tile , brick, etc.

* An exhaust vent is provided on the 

back of the appliance.

 

Built-in

 

Built-in

 

Free-standing

 

Free-standing

Observe related laws for installation.

Secure clearance for ventilation in the cabinet.

 

If a partition board without an intake part has been set

Cut both ends of the partition board or make holes using a holesaw.

 

Side view

For incombustible wall and ceiling (metal, tile, brick, etc.)

For combustible wall and ceiling

Bulge

* More than 40 cm

2

 

of total clearance area

More than 25 

for 

fl

 at part

If this condition is not met, 

do not install the appliance.

(unit: mm)

Summary of Contents for KY-E227D

Page 1: ...y that installation has been completed Signature of installer ZY16HD88 F0814K0 Installation Instructions Induction Heating Cooktop For domestic use KY E227D KY C227D KY A227D Model No ENGLISH Important Install the appliance according to the Installation Instructions Otherwise the performance of the appliance may be degraded The installer is responsible for proper installation Malfunctions or accid...

Page 2: ...the appliance Improper earthing may cause electric shock Before installation make sure to turn off the circuit breaker to prevent electric shock The power cord must be correctly connected to ensure the integrity of the connection Improper wire connections may cause electric leakage or fire If the power cord is damaged it must be replaced by the manufacturer its service agent or a similar qualified...

Page 3: ... 5 cm Min Min 5 cm 5 cm 4 5 If the front countertop has a bulge Installation Location Related Dimensions Built in Dimensions of countertop cutout Cut according to the template included with the appliance Including heat insulating board made of metal tile brick etc An exhaust vent is provided on the back of the appliance Built in Built in Free standing Free standing Observe related laws for install...

Page 4: ... the home electrical wire Wall socket Type of socket KY E227D KY C227D KY A227D BS546 type 15 A BS1363 type Installation Location Built in Install the socket at a location where the plug can be disconnected after installation Free standing Install the socket at a location where it is not exposed to hot air water or splattered food Warning Do not disassemble the top plate Before installation remove...