2.5 System Parameters
Programming Guide
133
1–9, 0, , #: Dial Codes
Feature Guide References
2.3.6 Call Transfer to Outside
Call Transfer to Outside Reconnect Sequence on No Answer
Specifies the sequence the VPS uses to reconnect the line when the transferred party does not
answer.
Value Range
Max. 16 digits consisting of 0–9, , # and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
N: Telephone Number Dialling
1–9, 0, , #: Dial Codes
Feature Guide References
2.3.6 Call Transfer to Outside
EFA Transfer Sequence
Specifies the sequence the VPS uses to transfer calls to Trunks using EFA (External Feature Access).
Note
•
The default value is only activated when the VPS is connected to default PBX (KX-TDA
series). For other PBX types, the default value differs depending on the EFA Transfer
Sequence specified in the PBX. For example, when the PBX type is changed to a KX-
TD1232/KX-TD500/KX-TA624 PBX, the default value becomes "F6TN".
Value Range
Max. 16 digits consisting of 0–9, , # and special codes
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
N: Telephone Number Dialling
1–9, 0, , #: Dial Codes
Summary of Contents for KX-TVM200
Page 98: ...2 4 Service Settings 98 Programming Guide Feature Guide References 2 3 15 Custom Service ...
Page 158: ...2 7 Reports 158 Programming Guide Feature Guide References 2 5 6 System Reports ...
Page 168: ...2 7 Reports 168 Programming Guide Feature Guide References 2 5 6 System Reports ...
Page 180: ...2 8 System Security 180 Programming Guide ...
Page 193: ...Programming Guide 193 Index ...
Page 199: ...Index Programming Guide 199 ...