54
KX-TG8421HGN/KX-TGA840FXN
(
K
)* Frequency Offset Confir-
mation
-
Follow steps 1 to 3 of
(I)
.
4.Confirm that the frequency Offset is < ± 50 kHz.
IC1,
C802~C806,
C808~C814,
C819~C820,
C822,
C825~C827,
C834,
C859~C864,
L801~L804,
DA801,
R801~R808
(
L
)* Frequency Drift Confir-
mation
-
Follow steps 1 to 3 of
(I)
.
4.Confirm that the frequency Drift is < ± 35 kHz/ms.
IC1,
C802~C806,
C808~C814,
C819~C820,
C822,
C825~C827,
C834,
C859~C864,
L801~L804,
DA801,
R801~R808
(
M
)*
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 3 of
(I)
.
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1,
C802~C806,
C808~C814,
C819~C820,
C822,
C825~C827,
C834,
C859~C864,
L801~L804,
DA801,
R801~R808
(
N
)* Power RAMP Confirma-
tion
-
Follow steps 1 to 3 of
(I)
.
4.Confirm that Power RAMP is matching.
IC1,
C802~C806,
C808~C814,
C819~C820,
C822,
C825~C827,
C834,
C859~C864,
L801~L804,
DA801,
R801~R808
(
O
) Audio Check and Confir-
mation
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 40 mA.
3. Input -45 dBm/1KHz to MIC and measure Line output level.
4. Confirm that the level is -9.0 dBm ± 2 dBm and that the distortion level is < 5%
at TEL Line (600
Ω
Load).
5. Input -20 dBm/1KHz to Line I/F and measure Receiving level at REV+ and
REV-.
6. Confirm that the level is -24.5 dBm ± 2 dBm and that the distortion level is < 5%
at Receiver. (vol = 2)
IC1, C12, D19,
D20, C96,
C97, R215,
R27, RA4,
C11, C13,
R28, D3, D4,
MIC, L9, RA2,
R73, R74
(
P
) SP phone Audio Check
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 40 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -25 dBm/1KHz to Line I/F and measure Receiving level at SP+ and SP-.
5. Confirm that the level is -9.5 dBm ± 2 dBm and that the distortion level is < 5%.
(vol = 3)
IC1, C12, C73,
D13, D14,
R152, R73,
R74, RA2,
MIC, C11,
C13, RA4,
R27, R28,
R208, R209,
C96, C97,
R215, C72
(
Q
) Charge Pump 2.5V Sup-
ply Confirmation
CP2.5V
1. Confirm that the voltage between testpoint CP2.5V and GND is 2.5V -0.1/
+0.3V.
C52, C53, C49
(
R
) Charge Pump 4.0V Sup-
ply Confirmation
CP4.0V
1. Confirm that the voltage between testpoint CP4.0V and GND is 4.0V I0.2V.
C50, C51
Items
Check
Point
Procedure
Check or
Replace Parts
Summary of Contents for KX-TGA840FXN
Page 2: ...2 KX TG8421HGN KX TGA840FXN ...
Page 14: ...14 KX TG8421HGN KX TGA840FXN 4 6 Signal Route ...
Page 15: ...15 KX TG8421HGN KX TGA840FXN ...
Page 21: ...21 KX TG8421HGN KX TGA840FXN 7 1 2 Answering System Settings 7 1 3 SMS Settings ...
Page 24: ...24 KX TG8421HGN KX TGA840FXN 7 6 Troubleshooting ...
Page 25: ...25 KX TG8421HGN KX TGA840FXN Cross Rreference For Service Hint P 28 ...
Page 26: ...26 KX TG8421HGN KX TGA840FXN ...
Page 27: ...27 KX TG8421HGN KX TGA840FXN ...
Page 28: ...28 KX TG8421HGN KX TGA840FXN 7 7 For Service Hint Cross Reference Battery Charge P 17 ...
Page 29: ...29 KX TG8421HGN KX TGA840FXN 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 31: ...31 KX TG8421HGN KX TGA840FXN 8 1 2 Handset ...
Page 40: ...40 KX TG8421HGN KX TGA840FXN Cross Reference Check Point Base Unit P 48 ...
Page 42: ...42 KX TG8421HGN KX TGA840FXN Cross Reference Check Point Handset P 52 ...
Page 57: ...57 KX TG8421HGN KX TGA840FXN ...
Page 58: ...58 KX TG8421HGN KX TGA840FXN 10 1 2 Handset ...
Page 59: ...59 KX TG8421HGN KX TGA840FXN 10 1 3 Charger Unit ...
Page 60: ...60 KX TG8421HGN KX TGA840FXN 10 2 How to Replace the Handset LCD ...
Page 85: ...85 KX TG8421HGN KX TGA840FXN Memo ...
Page 97: ...97 KX TG8421HGN KX TGA840FXN 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 98: ...98 KX TG8421HGN KX TGA840FXN 15 4 Accessories and Packing Materials 15 4 1 KX TG8421HGN ...
Page 99: ...99 KX TG8421HGN KX TGA840FXN 15 4 2 KX TGA840FXN ...