46
KX-TG7341BX/KX-TGA731BX
(
H
)* Hookswitch Check with
DC Characteristics
-
1. Connect Telephone Socket to Tel-simulator which is connected with 600
Ω
.
2. Set line voltage to 48 V and line current to 40mA at off-hook condition of nor-
mal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
L1, L2, Q3, R14,
R15, Q4, R16,
R17, D3,
R18~R24,
C15~C17
,
D21,
Q5, R27, IC7
(
I
) DTMF Generator Check
-
1. Connect Telephone Socket to DTMF tester. (Load=600
Ω
)
2. Link Handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -6 ± 2 dBm.
5. Confirm that the low Group is -8 ±2 dBm.
IC7, R25, C21,
R29, C22, C23,
D21
(
J
)* Transmitted Power Con-
firmation
-
ANTI_TP
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
2. Execute the command ”sendchar TST”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 19.0 dBm ~ 25.0 dBm.
IC7, L104,
C101, C106,
C102, C109,
R65, R66, DA1,
R802~R807,
C837, C826,
C822, C820,
C832, C833,
C63, Q401,
C402, C105,
C110, C65,
IC801, D801,
D802,
C801~C804,
C808~C814,
L802~L804,
C819, C834,
C825
(
K
)* Modulation Check and
Adjustment
-
ANTI_TP
Follow steps 1 to 6 of
(J)
.
7.Confirm that the B-Field Modulation is -370 ± 30/ +370± 30 kHz/div & Modu-
lated width 690 kHz using data type Fig31.
8.Adjust the B-Field Modulation if required. (Execute the command “readmod”
and “wrtmod xx”, where xx is the value.)
IC7, L104,
C101, C106,
C102, C109,
R65, R66, DA1,
R802~R807,
C837, C826,
C822, C820,
C832, C833,
C63, Q401,
C402, C105,
C110, C65,
IC801, D801,
D802,
C801~C804,
C808~C814,
L802~L804,
C819, C834,
C825
(
L
)* Frequency Offset Check
-
ANTI_TP
Follow steps 1 to 6 of
(J)
.
7.Confirm that the frequency offset is < ± 10 kHz.
IC7, L104,
C101, C106,
C102, C109,
R65, R66, DA1,
R802~R807,
C837, C826,
C822, C820,
C832, C833,
C63, Q401,
C402, C105,
C110, C65,
IC801, D801,
D802,
C801~C804,
C808~C814,
L802~L804,
C819, C834,
C825
Items
Check
Point
Procedure
Check or
Replace Parts
Summary of Contents for KX-TG7341BXM
Page 2: ...2 KX TG7341BX KX TGA731BX ...
Page 14: ...14 KX TG7341BX KX TGA731BX 4 6 Signal Route ...
Page 15: ...15 KX TG7341BX KX TGA731BX ...
Page 17: ...17 KX TG7341BX KX TGA731BX 6 Installation Instructions 6 1 Connections ...
Page 22: ...22 KX TG7341BX KX TGA731BX 7 6 Troubleshooting ...
Page 23: ...23 KX TG7341BX KX TGA731BX ...
Page 24: ...24 KX TG7341BX KX TGA731BX ...
Page 25: ...25 KX TG7341BX KX TGA731BX 7 7 For Service Hint Cross Reference Battery Charge P 18 ...
Page 26: ...26 KX TG7341BX KX TGA731BX 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 28: ...28 KX TG7341BX KX TGA731BX 8 1 2 Handset ...
Page 37: ...37 KX TG7341BX KX TGA731BX Cross Reference Check Point Base Unit P 45 ...
Page 39: ...39 KX TG7341BX KX TGA731BX Cross Reference Check Point Handset P 49 ...
Page 54: ...54 KX TG7341BX KX TGA731BX ...
Page 55: ...55 KX TG7341BX KX TGA731BX 10 1 2 Handset ...
Page 56: ...56 KX TG7341BX KX TGA731BX 10 1 3 Charger Unit ...
Page 57: ...57 KX TG7341BX KX TGA731BX 10 2 How to Replace the Handset LCD ...
Page 79: ...79 KX TG7341BX KX TGA731BX Memo ...
Page 96: ...96 KX TG7341BX KX TGA731BX 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 97: ...97 KX TG7341BX KX TGA731BX 15 4 Accessories and Packing Materials 15 4 1 KX TG7341BXM BXT ...
Page 98: ...98 KX TG7341BX KX TGA731BX 15 4 2 KX TGA731BXB BXF BXS ...