45
KX-TG7341BX/KX-TGA731BX
9.2.
Troubleshooting by Symptom (Base Unit and Charger Unit)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to
Check Point (Base Unit)
(P.45)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC or EEPROM or FLASH is replaced.
Note:
After the measuring, suck up the solder of TP.
*:
PC Setting
(P.58) is required beforehand.
The connections of simulator equipments are as shown in
Adjustment Standard (Base Unit)
(P.60).
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
) 3.0 V Supply Confirma-
tion
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.0 V ± 0.2 V.
IC1, C50, C51,
C52, R50, R51,
C53, F1, D1
(
B
) 1.8 V Supply Confirma-
tion
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.1 V.
Q8, C55, C61,
C64, IC7
(
C
) Charge Pump
2.5 V Supply Confirma-
tion
VDD5
1. Confirm that the voltage between test point VDD5 and GND is 2.5 V -0.1/+0.3
V.
IC7, C404
(
D
) Charge Pump
3.0 V Supply Confirma-
tion
VDD4
1. Confirm that the voltage between test point VDD4 and GND is 3.0 V ± 0.2 V. IC7, C422, C425
(
E
)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC7, X1, R76,
R69, R70
(
F
)* EEPROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command “ChkTG7340XXrevYY.bat”).
XX: country code
YY: revision number
2. Confirm the returned checksum value.
3. The checksum is displayed in the last output line.
Note:
“XX”, “YY”, and “checksum” vary depending on the country version. You can find
them in the batch file, PQZZ- mentioned in
JIG and PC
(P.58).
IC7, RA401,
C401, R405,
IC401
(
G
)* BBIC Clock Adjustment
CLK
VDD4
1. Input Command “ sendchar WWD ff 48 IC 8006”
2. Confirm that the voltage between testpoint VDD4 and GND is less than 1.0 V.
3. Input Command “ sendchar sfr”, then you can confirm the current value.
4. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
5. If the frequency is not 10.368MHz ± 100Hz, adjust the frequency of CLK exe-
cuting the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
X1, IC7, C66
Summary of Contents for KX-TG7341BXM
Page 2: ...2 KX TG7341BX KX TGA731BX ...
Page 14: ...14 KX TG7341BX KX TGA731BX 4 6 Signal Route ...
Page 15: ...15 KX TG7341BX KX TGA731BX ...
Page 17: ...17 KX TG7341BX KX TGA731BX 6 Installation Instructions 6 1 Connections ...
Page 22: ...22 KX TG7341BX KX TGA731BX 7 6 Troubleshooting ...
Page 23: ...23 KX TG7341BX KX TGA731BX ...
Page 24: ...24 KX TG7341BX KX TGA731BX ...
Page 25: ...25 KX TG7341BX KX TGA731BX 7 7 For Service Hint Cross Reference Battery Charge P 18 ...
Page 26: ...26 KX TG7341BX KX TGA731BX 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 28: ...28 KX TG7341BX KX TGA731BX 8 1 2 Handset ...
Page 37: ...37 KX TG7341BX KX TGA731BX Cross Reference Check Point Base Unit P 45 ...
Page 39: ...39 KX TG7341BX KX TGA731BX Cross Reference Check Point Handset P 49 ...
Page 54: ...54 KX TG7341BX KX TGA731BX ...
Page 55: ...55 KX TG7341BX KX TGA731BX 10 1 2 Handset ...
Page 56: ...56 KX TG7341BX KX TGA731BX 10 1 3 Charger Unit ...
Page 57: ...57 KX TG7341BX KX TGA731BX 10 2 How to Replace the Handset LCD ...
Page 79: ...79 KX TG7341BX KX TGA731BX Memo ...
Page 96: ...96 KX TG7341BX KX TGA731BX 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 97: ...97 KX TG7341BX KX TGA731BX 15 4 Accessories and Packing Materials 15 4 1 KX TG7341BXM BXT ...
Page 98: ...98 KX TG7341BX KX TGA731BX 15 4 2 KX TGA731BXB BXF BXS ...