49
KX-TG7341BX/KX-TGA731BX
9.3.
Troubleshooting by Symptom (Handset)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to
Check Point (Handset)
(P.49)
9.3.1.
Check Point (Handset)
Please follow the items below when BBIC or EEPROM is replaced.
Note:
After the measuring, suck up the solder of TP.
*:
PC Setting
(P.62) is required beforehand.
The connections of adjustment equipments are as shown in
Adjustment Standard (Handset)
(P.64).
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
)* 1.8 V Supply Adjustment
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.
2. Execute the command “VDD”, then check the current value.
3. Adjust the 1.8V voltage of VDD1 executing command “VDD XX“(XX is the
value).
IC1, Q2, C48,
D1, C1, C44,
R12, C3, R45,
C40, C45, F1,
L8
(
B
)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC1, X1, RA61,
R64, R66
(
C
)* EEP-ROM Confirmation
-
1. EEP-ROM Confirmation (Execute the command “ChkTGA731XXrevYY.bat”).
XX: country code
YY: revision number
2. Confirm the returned checksum value.
Note:
“XX”, “YY”, and “checksum” vary depending on the country version. You can find
them in the batch file, PQZZ- mentioned in
JIG and PC
(P.62).
IC1, IC3,
R40~R42,
C172
(D) Charge Control Check &
Charge Current Monitor
Check
-
1. Apply 3.5 V between CHG(+) and CHG(-) with DC power supply and set cur-
rent limit to 250 mA.
Confirm the indication of “charging” on LCD.
2. Confirm that the current limit LED of DC power supply is ON/OFF.
Confirm it after waiting over 1 minute at least.
3. Decrease current limit of DC power supply to 100 mA.
4. Confirm that the current limit LED of DC power supply is stable. (Current limiter
is ON.)
(If charge control cannot be confirmed by this procedure, please use battery to hand-
set power supply and try again.)
IC1, Q4 Q9,
D7, D8, L4, L5,
R6, R7, F1,
C1, C3, R2,
R30, R31, R8,
C147, R45,
C15
,
L8
Summary of Contents for KX-TG7341BXM
Page 2: ...2 KX TG7341BX KX TGA731BX ...
Page 14: ...14 KX TG7341BX KX TGA731BX 4 6 Signal Route ...
Page 15: ...15 KX TG7341BX KX TGA731BX ...
Page 17: ...17 KX TG7341BX KX TGA731BX 6 Installation Instructions 6 1 Connections ...
Page 22: ...22 KX TG7341BX KX TGA731BX 7 6 Troubleshooting ...
Page 23: ...23 KX TG7341BX KX TGA731BX ...
Page 24: ...24 KX TG7341BX KX TGA731BX ...
Page 25: ...25 KX TG7341BX KX TGA731BX 7 7 For Service Hint Cross Reference Battery Charge P 18 ...
Page 26: ...26 KX TG7341BX KX TGA731BX 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 28: ...28 KX TG7341BX KX TGA731BX 8 1 2 Handset ...
Page 37: ...37 KX TG7341BX KX TGA731BX Cross Reference Check Point Base Unit P 45 ...
Page 39: ...39 KX TG7341BX KX TGA731BX Cross Reference Check Point Handset P 49 ...
Page 54: ...54 KX TG7341BX KX TGA731BX ...
Page 55: ...55 KX TG7341BX KX TGA731BX 10 1 2 Handset ...
Page 56: ...56 KX TG7341BX KX TGA731BX 10 1 3 Charger Unit ...
Page 57: ...57 KX TG7341BX KX TGA731BX 10 2 How to Replace the Handset LCD ...
Page 79: ...79 KX TG7341BX KX TGA731BX Memo ...
Page 96: ...96 KX TG7341BX KX TGA731BX 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 97: ...97 KX TG7341BX KX TGA731BX 15 4 Accessories and Packing Materials 15 4 1 KX TG7341BXM BXT ...
Page 98: ...98 KX TG7341BX KX TGA731BX 15 4 2 KX TGA731BXB BXF BXS ...