50
KX-TG7100BXS/KX-TG7100BXT/KX-TGA710CXS/KX-TGA710CXT
11.5. Things to Do after Replacing IC
Cautions:
Since this page is common to each country, it may not apply to some models in your country. The contents below are the mini-
mum adjustments required for operation.
11.5.1. Base Unit
Before doing the following adjustment, be sure to do
PC Setting
(P.44) in
The Setting Method of JIG (Base Unit)
.
Note:
(*1) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.44).
(*2) Refer to
Check Point (Base Unit)
(P.33)
11.5.2. Handset
Before doing the following adjustment, be sure to do
PC Setting
(P.45) in
The Setting Method of JIG (Handset)
.
Note:
(*3) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.44).
(*4) Refer to
Check Point (Handset)
(P.36)
IC
Necessary Adjustment
BBIC
(IC7)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Country version batch file: Execute the command
“TG7100XXrevYY.bat”. (*1)
3. Clock adjustment: Refer to Check Point (F). (*2)
EEPROM
(IC5)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0000” of EEPROM to “00”.
2. Default batch file: Execute the command “default.bat”.
3. Country version batch file: Execute the command
“TG7100XXrevYY.bat”. (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
IC
Necessary Adjustment
BBIC
(IC1)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Default batch file (remaining); Execute the command
“TGA710 DEFrevYY.bat”. (*3)
3. Country version batch file: Execute the command
“TGA710XXrevYY”. (*3)
4. Clock adjustment: Refer to Check Point (J). (*4)
5. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
EEPROM
(IC3)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0015” of EEPROM to “00”.
2. Default batch file: Execute the command “default.bat”.
3. Default batch file (remaining); Execute the command
“TGA710 DEFrevYY.bat”. (*3)
4. Country version batch file: Execute the command
“TGA710XXrevYY”. (*3)
5. Clock adjustment: Refer to Check Point (J). (*4)
6. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
Summary of Contents for KX-TG7100BXS
Page 2: ...2 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT ...
Page 13: ...13 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 4 5 Signal Route ...
Page 19: ...19 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 7 4 For Service Hint ...
Page 22: ...22 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 8 1 2 Handset ...
Page 42: ...42 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 10 1 2 Handset ...
Page 43: ...43 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 10 2 How to Replace the Handset LCD ...
Page 58: ...58 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT Memo ...
Page 70: ...70 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 15 3 Accessories and Packing Materials ...